Electrical Installation
Proceed as follows to connect the field distributor to the energy bus:
1. Remove the fastening screws of the hood and slightly lift the hood.
2. If necessary: Remove the electrical plug connection X8 between upper and lower part
and remove the upper part.
3. Remove the two fastening screws, open up the base and place the flat cable inside in the
right direction (according to the coding).
4. Close the base and secure it with the two fastening screws.
Procedure
Procedure
Hood fastening screws
Opened base
Flat cable inserted and base closed