![widos 7000 WM Working Instructions Translation Download Page 56](http://html1.mh-extra.com/html/widos/7000-wm/7000-wm_working-instructions-translation_979319056.webp)
Ku nst sto ffschweißtec hni k
WIDOS
Einsteinstr. 5
Phone +49 (0) 71 52 99 39 - 0
W. Dommer Söhne GmbH D-71254 Ditzingen-Heimerdingen
Fax
+49 (0) 71 52 99 39 - 40
Website: www.widos.de
Email: [email protected]
25.11.11
Working Instructions WIDOS 7000 WM
page 56 of 98
7. Diagnosis program
The purpose of the diagnosis program is the control and the modification of stored machine
parameters.
In the following lines all important diagnosis numbers for the function tests are described.
Inappropriate operation of the diagnosis functions may lead to disturbances in the
machine and may destroy components.
The diagnosis functions allow direct access to the specific parameters of the
machine and have to be operated only by skilled staff.
Display:
2nd line:
WIDOS 70031 SPA
09:43 25.10.2008
Basic menu
Press simultaneously buttons <+> and <Enter> to enter the diagnosis
program from the basic menu.
Display:
2nd line:
WIDOS 70031 SPA
0000
Enter the diagnosis number
Enter the required diagnosis number by pressing buttons <+>, <
−
> and
<Enter>.
One step back by pressing buttons <Enter> (keeping pressed) and <->.
No.
Signification
0010
- The actual temperature (°C) of the heating element is displayed
0011
- The environmental temperature (°C) is displayed
0012
- The pressure or the force (bar or N) is displayed
0014
- The required heating time which was calculated by the programmed welding
parameters is displayed
0015
- The required change over time which was calculated by the programmed
welding parameters is displayed
0016
- The required time for pressure ramp which was calculated by the
programmed welding parameters is displayed
0017
- The required cooling time which was calculated by the programmed welding
parameters is displayed
0018
- The required cooling pressure is displayed
0022
- Selection of SDR / wall thickness in the display
0000
mm
0002
SDR
0023
- The automatic change to summer or winter time may be switched on or off
0: change summer / winter time switched off
1: change summer / winter time switched on