www.whisperkool.com | Page 15
SC PRO Series
LIQUID-MEASURING THERMOSTAT SYSTEM (BOTTLE PROBE)
WhisperKOOL cooling units come with a liquid-temperature-measuring thermostat. The self-calibrating bottle probe
contains a sensor chip, which communicates back and forth with the thermostat. This results in a consistent tempera-
ture setting and accuracy. Wine should be kept at a very precise, controlled temperature and humidity. By measuring
the liquid temperature rather than air, the unit will operate 75–80% of the time.
Setting up the Bottle Probe:
1. Locate an empty wine bottle.
2. Fill it 75% full with room-temperature tap water.
3. Place bottle probe securely into bottle as seen in Figure 1.
4. Place the wine bottle in your wine cellar. Ensure sensor tip is fully submerged.
5. To ensure a consistent temperature, place bottle probe approximately three
(3) feet away from the air output and not in the flow of the air.
It is recommended that the bottle be placed in a central location of your
wine cellar. Avoid pulling too much on the probe cord. It may become
disconnected resulting in limited functionality of the unit.
Note: The thermostat can be set between 50-70°F.
Remember: The unit operates based on the temperature of the water.
Do not be misled by thermostats reading air temperature. The air temperature
in the cellar will be cooler than the liquid temperature of the wine while it is
reaching the optimum balanced temperature.
Figure 1
Summary of Contents for SC PRO 2000
Page 1: ...SC PRO SERIES OWNER S MANUAL SC PRO 2000 SC PRO 3000 SC PRO 4000...
Page 21: ...www whisperkool com Page 19 SC PRO Series WIRING SCHEMATIC...
Page 22: ...SC PRO 111519 Page 20 1 800 343 9463 WIRING SCHEMATIC...
Page 23: ...www whisperkool com Page 21 SC PRO Series NOTES...
Page 32: ...WhisperKOOL 1738 E Alpine Ave Stockton CA 95205 1 800 343 9463 www whisperkool com...