![Whirlpool MID-LINE DESIGN User Manual Download Page 89](http://html.mh-extra.com/html/whirlpool/mid-line-design/mid-line-design_user-manual_972728089.webp)
83
Bi-Metal
The Bi-Metal can be tested by using the test lead plug located in the control box. The test lead plug
is connected to a brown and a pink wire.
To Test the Bi-Metal: (All models except Mullion Evaporator Design)
1. Follow the procedure for removing the control box on the specific unit being serviced.
2. Locate the test lead plug (a brown and a pink wire) inside the control box.
3. Set the volt-ohm meter to the Rx1 scale. Be sure the freezer section is at operating tem-
perature (cold).
4. Place the probes of a VOM in the two terminals of the test lead plug. The VOM should read
continuity.
Brown
Wire
Pink
Wire
Bi-Metal
To Test the Bi-Metal: (Mullion Evaporator
Design)
1. Follow the procedure for removing the
control box on the specific unit being
serviced.
2. Locate the test leads (a black and a blue
wire) located with the defrost timer.
3. Set the volt-ohm meter to the Rx1 scale.
Be sure the freezer section is at operating
temperature (cold). The defrost timer must
be set for defrost and the defrost contacts
closed.
4. Place the probes of a VOM to the two
test leads. The VOM should read
continuity.