SEALED SYSTEM DIAGNOSIS REVIEW
Entering and properly processing the sealed refrigeration system requires special equipment and
should only be accomplished by a qualified service technician.
Before suspecting that the sealed refrigeration system has failed, be sure to check out all other possi-
bilities as described in the following Troubleshooting Chart on pages 73-79.
There are four conditions that make entering the sealed system necessary.
1. Incorrect amount of refrigerant
2. Restriction of refrigerant flow
3. Refrigerant leak
4. Compressor not operating correctly
Current U. S. Environmental Protection Agency regulations require specific procedures and equip-
ment for the collection and disposal of any refrigerant used in the sealed system of a domestic refrig-
erator, freezer, ice machine or air conditioner. As a result, if it is determined that the sealed system
must be repaired, contact a qualified and certified service technician to perform the repairs.