![Whirlpool MID-LINE DESIGN User Manual Download Page 27](http://html.mh-extra.com/html/whirlpool/mid-line-design/mid-line-design_user-manual_972728027.webp)
21
OLD DESIGN
12 & 14 cu. ft. Top-Mount
Servicing the Thermostat
The thermostat is mounted in the cross rail area
by two (2) mounting screws.
When removing the thermostat the sensing tube
will also have to be removed. The sensing tube is
routed back to the deffuser. To access the sensing
tube, remove the two (2) screws securing the deffuser cover.
(Fig. 29)
SENSOR TUBE
THERMOSTAT
Servicing the Evaporator Fan
Access to the Evaporator Fan is possible once the Evaporator Cover has been removed.
1. Remove the evaporator mounting screws and remove the evaporator cover.
(Fig. 30)
2. Remove the four (4) screws securing the fan shroud to the back wall of the freezer section
and lift the shroud off.
(Fig. 31)
3. Remove the two (2) screws securing the fan motor mounting bracket to the back wall of the
freezer section and lift the fan motor assembly from its location.
(Fig. 31)
4. Disconnect the wiring harness connector from the fan motor terminals.
SHROUD
MOUNTING
SCREW
SHROUD
MOUNTING
SCREW
SHROUD MOUNTING
SCREW
SHROUD MOUNTING
SCREW
FAN MOUNTING SCREW
FAN MOUNTING SCREW
Servicing the Bi-Metal
The Bi-Metal
(Fig. 32) is attached to the heat shield
on the back wall of the freezer section.
1. Gently pry the bi-metal retaining clip up
and slide the bi-metal out from under the clip.
2. Disconnect the bi-metal wire connector from
the wiring harness plug.
Fig. 31
Fig. 29
BIMETAL
Fig. 32
MOUNTING
SCREWS
MOUNTING
SCREWS
SHELF STUDS
Fig. 30
Summary of Contents for MID-LINE DESIGN
Page 6: ...VI NOTES ...
Page 18: ...12 MULLION EVAPORATOR DESIGN 12 cu ft Top Mount NOTES ...
Page 32: ...26 OLD DESIGN 12 14 cu ft Top Mount REFRIGERATOR LIGHT CIRCUIT MULLION HEATER CIRCUIT ...
Page 76: ...70 MID LINE DESIGN 16 thru 22 cu ft Top Mount NOTES ...
Page 107: ...VII ...
Page 108: ...VIII CORPORATION ...