![Whirlpool MID-LINE DESIGN User Manual Download Page 5](http://html.mh-extra.com/html/whirlpool/mid-line-design/mid-line-design_user-manual_972728005.webp)
V
PRODUCT IDENTIFICATION
12 cu. ft. “Mullion Evaporator Design” -
Distinguishing Characteristics:
• Air return louvers located at the front of
the freezer floor.
• A stack condenser on the back of the
unit.
• Has heat loop mullion and stile heat.
• Evaporator located in the divider be-
tween the freezer and refrigerator sec-
tions.
• Roper brand only
12 & 14 cu. ft. “Old Design” -
Distinguishing Characteristics:
• Air discharge louvers located at the top
rear of the freezer section.
• A stack condenser on the back of the
unit.
• Has electric mullion and stile heaters.
• Evaporator vertically mounted behind
rear panel of freezer compartment.
• May be equipped with Adaptive Defrost
Control.
14 cu. ft. “New Design” -
Distinguishing Characteristics:
• Air tower at the rear of the freezer section
with horizontal louvers.
• Has heat loop mullion and stile heat.
• A stack condenser on the back of the
unit.
• Model “F” designation
• Manufactured from 1993 to present
16, thru 22 cu. ft. “Mid-Line Design” -
Distinguishing Characteristics:
• Air tower at the rear of the freezer section
with vertical louvers.
• Has heat loop mullion and stile heat.
• A forced air condenser at the bottom of
the unit.
• Manufactured from 1994 to present.
Four distinct series of top-mount refrigerator/freezers will be covered in the Job Aid. Each series can
be identified by a number of distinguishing features:
A) Air circulation in the freezer compartment
B) Type of condenser
C) Location of the Evaporator
D) Method of outside condensation control
Air Tower
with
Vertical Louvers
Air Tower
with
Horizontal Louvers
Louvers Across
Top Rear
Louvers at Front of
Freezer Floor
Component Access - Section One, page 6.
Wiring Diagram - Section One, page 10.
Component Access - Section Two, page 19.
Wiring Diagram - Section Two, page 24.
Adaptive Defrost Control - Section Six, page 92.
Component Access - Section Three, page 36.
Wiring Diagram - Section Three, page 46.
Component Access - Section Four, page 55.
Wiring Diagram - Section Four, page 64.
Summary of Contents for MID-LINE DESIGN
Page 6: ...VI NOTES ...
Page 18: ...12 MULLION EVAPORATOR DESIGN 12 cu ft Top Mount NOTES ...
Page 32: ...26 OLD DESIGN 12 14 cu ft Top Mount REFRIGERATOR LIGHT CIRCUIT MULLION HEATER CIRCUIT ...
Page 76: ...70 MID LINE DESIGN 16 thru 22 cu ft Top Mount NOTES ...
Page 107: ...VII ...
Page 108: ...VIII CORPORATION ...