4-5
Refer to page 3-11 for the procedure for servic-
ing the high voltage transformer.
1.
Disconnect the electrical power to the
microwave oven.
2.
Disconnect the high voltage transformer
wires from the magnetron and high volt-
age capacitor terminals.
3.
Set the ohmmeter to the R x 1 scale.
4.
Touch the ohmmeter leads to the two
primary terminals. The meter should indi-
cate less than 1
Ω
.
5.
Touch one ohmmeter lead to the white
secondary wire terminal and the other
lead to the transformer chassis ground
lug. The meter should indicate between
65 and 120
Ω
.
6.
Touch the ohmmeter leads to the two red-
black filament terminals. The meter should
indicate 0
Ω
.
7.
Set the ohmmeter to the R x 1K scale.
8.
Touch one ohmmeter lead to the trans-
former chassis ground lug. Touch the other
lead to each of the filament terminals. The
meter should indicate infinity at both termi-
nals.
THE HIGH VOLTAGE TRANSFORMER
Black
White
Red-Black
Red-Black
White
Filament Terminals
(Red-Black)
Secondary (White)
To HV Capacitor
To HV Cap
(Red-Blk)
Primary
(Blk & Wht)
ELECTRICAL SHOCK HAZARD
Disconnect power before servicing.
Replace all panels before operating.
Failure to do so could result in death or
electrical shock.
WARNING
High Voltage Transformer