3-13
ELECTRICAL SHOCK HAZARD
Disconnect power before servicing.
Replace all panels before operating.
Failure to do so could result in death or
electrical shock.
REMOVING THE VENT MOTOR
1.Disconnect the electrical power to the
microwave oven.
2.Remove the glass turntable and roller
assembly from inside the oven cavity.
CAUTION:
When you work on the microwave
oven, be careful when handling the sheet metal
parts. Sharp edges may be present, and you
can cut yourself if you are not careful.
WARNING
3.Remove the microwave oven from its
mounting location.
4.Remove the three screws from the air vent
cover on the top of the cabinet and remove
the cover.
Roller
Assembly
Glass
Turntable
5.Remove the vent motor mounting screw
from the rear panel.
6.Lift the vent motor out of the opening at the
rear of the oven and disconnect the power
connector from the main harness connec-
tor.
Vent Motor Screw
Vent Motor Power Connector
Air Vent Cover
3 Screws