3-6
REMOVING THE DOOR SWITCHES
CAUTION:
When you work on the microwave
oven, be careful when handling the sheet metal
parts. Sharp edges may be present, and you
can cut yourself if you are not careful.
1.Disconnect the electrical power to the
microwave oven.
2.Remove the control panel from the micro-
wave oven (see page 3-4 for the proce-
dure).
3.
To remove the primary interlock switch:
a) Disconnect the wire connectors from
the terminals.
b) Carefully raise the locking arm, pull out,
and remove the switch from the bracket.
4.
To remove the monitor switch or sec-
ondary interlock switch:
a) Disconnect the wire connectors from
the terminals.
b) Carefully push in on the locking arm
(be careful not to break it off) while you
twist the switch on the pivot pin, and
remove the switch from the bracket.
NOTE: If a locking arm breaks, you will
have to replace the entire bracket, so
be careful when bending the arms.
2 White
Wires
2 White Wires
(1 Large & 1 Small)
Raise Locking Arm
Pull Out Here
ELECTRICAL SHOCK HAZARD
Disconnect power before servicing.
Replace all panels before operating.
Failure to do so could result in death or
electrical shock.
WARNING
Monitor
Switch
Secondary
Interlock Switch
Push Locking Arm
Push Locking Arm
Red
White &
Yellow
Green
Yellow
Primary
Interlock Switch
Primary
Interlock Switch
Monitor
Switch
Secondary
Interlock Switch