4-4
d) Disconnect the wire connectors from
the pressure switch terminals.
(23)
WH
(22)
PK
(11)
WH-BK
(21)
WH-BK
(13)
VT
11.
To remove the water inlet valves:
a) At the rear of the top cover, remove the
two 5/16
″
hex-head screws from the
water inlet valves.
b) Remove the pressure switch from the
dispenser housing (see step 10a).
c) Remove the two 7/32
″
hex-head
screws from the dispenser housing.
Water Inlet Valve Screws
d) Remove the dispenser housing and
water inlet valves from the top cover
and position the cover with the wire
connectors facing you.
e) Disconnect the wire connectors from
the water inlet valve terminals.
f) Disconnect the green ground wire from
the water inlet valve bracket tab.
Dispenser
Housing Screws
g) Slide the water inlet valves out of their
mounting bracket.
RD-YL
2 PK
PK
BN-RD
GN-YL
Electrical Shock Hazard
Connect green ground wire to ground
terminal.
Failure to do so can result in death or
electrical shock.