2-5
Excessive Weight Hazard
Use two or more people to move and
install washer.
Failure to do so can result in back or
other injury.
WARNING
BEFORE YOU START
• To prevent floor damage, set the washer
onto cardboard before moving across floor.
• Move the washer to within approximately 3 ft
(90 cm) of the final location.
DRAIN SYSTEM
The washer can be installed using the standpipe
drain system (floor or wall), the laundry tub
drain system, or the floor drain system. Select
the drain hose installation method you need.
Standpipe drain system - wall or floor
(views A & B)
The standpipe drain requires a minimum diam-
eter standpipe of 2
″
(5 cm). The minimum
carry-away capacity can be no less than
13 gallons (49.2 L) per minute. A 2
″
(5 cm)
diameter to 1
″
(2.5 cm) diameter standpipe
adapter kit is available (see “Alternate Parts”
on page 2-2).
The top of the standpipe must be at least
39
″
(99 cm) high and no higher than 72
″
(183 cm)
from the bottom of the washer.
Laundry tub drain system (view A)
The laundry tub requires a minimum carry-
away capacity of 13 gal. (49.2 L) per minute.
The top of the laundry tub must be at least 39
″
(99 cm) above the floor and no higher than 72
″
(183 cm) from the bottom of the washer.
Floor drain system (view B)
The floor drain system requires a siphon break
that may be purchased separately (see “Alter-
nate Parts” on page 2-2).
The siphon break must be a minimum of 28
″
(71 cm) from the bottom of the washer. Addi-
tional hoses might be needed.
The minimum carry-away capacity can be no
less than 13 gallon (49.2 L) per minute.
A
B
39"
(99 cm)
CONNECT DRAIN HOSE
Proper connection of the drain hose will protect
your floors from damage due to water leakage.
To prevent the drain hose from coming off or
leaking, it must be installed per the following
instructions.
IMPORTANT:
To ensure proper installation,
this procedure must be followed exactly.
1.
Check the drain hose to see that it is the
proper length.
2.
Wet the inside of the straight end of the
drain hose with tap water.
IMPORTANT:
Do not use any lubricant other than water.
39"
(99 cm)
A
B
PERMANENT INSTALLATION INSTRUCTIONS