45
Cable Specifications
Type
Model
Power cord
Power connecting
Main power
cable
supply (Note)
Split On/off
ASV09000R
ASV12000R
ASV18000R
ASV22000R
ASH09000R
ASH12000R
ASH18000R
ASH22000R
3G1.0
3G1.0
3G1.5
3G2.5
3G1.0
3G1.0
3G1.5
3G2.5
4G1.0
4G1.0
4G1.5
4G2.5
4G1.0
4G1.0
4G1.5
4G2.5
To indoor
To indoor
To indoor
To indoor
To indoor
To indoor
To indoor
To indoor
Connecting the cable
CAUTION:
1. Make sure that the colour of wires and the terminal number of the outdoor unit
are the same as those of the indoor unit.
2. Use an individual power circuit specifically for the air conditioner. As for the
wiring method, refer to the circuit diagram on the appliance.
3. Check that the cable specification conforms to the table as follows.
4. Check the wires and make sure that they are all tightly fastened after cable
connection. The cable should be tightly fastened by cable clamp.
5. Be sure to install an earth leakage circuit breaker in a wet or moist area.