32
4.Put wiring cover back and then tighten the screw.
5.Close the panel.
Installation of indoor unit
Note:
Ɣ All wires of indoor unit and outdoor unit should be connected by a professional.
for a new one. Avoid extending the wire by yourself.
installation.
Ɣ)RUWKHDLUFRQGLWLRQHUZLWKRXWSOXJDQair switch must be installed in the line.
The air switch should be all-pole parting and the contact parting distance should
be more than 3mm.
power connection
wire
cable-cross
hole
2. Make the power connection wire go
through the cable-cross hole at the back
of indoor unit and then pull it out from
the front side.
3. Remove the wire clip; connect the power connection wire to the wiring terminal
with wire clip.
Outdoor unit connection
N(1) 2
3
brown
black
blue
yellow-
green
35
* Please refer to Page 45 of "Connecting the cable", which is regarding the
cable specifications and requirements.
Summary of Contents for ASH09000R
Page 13: ...Introduction for buttons on remote controller 10 Note ...
Page 29: ...26 Installation dimension diagram ...
Page 82: ...室內機的安裝 79 持 ...
Page 86: ...室內機的安裝 83 ...