THE DOOR LOCK SOLENOID & DOOR LATCH SWITCH
open) position. During the self-clean cycle, the
control board sends a 120-volt pulse to the so-
lenoid windings, which pulls the plunger in, and
moves the latch actuator rod to lock the oven
door (Figure 3-6B). The movement of the rod
also actuates the door latch switch and closes
it. When the self-clean cycle is over, the con-
trol board sends a 120-volt pulse to the sole-
noid, the plunger is pushed out, the latch ac-
tuator rod releases the door, and the door latch
switch opens.
The door lock solenoid operates on a 120-volt
pulse from the electronic control board. When
the door is in the unlocked position, (Figure
3-6A), the plunger is extended. When the door
latch switch is open, the control senses that
the door is unlocked. When the door latch
switch closes, the control senses that the door
is locked. The door latch switch, mounted on
the solenoid bracket, is in the N.O. (normally-
PLUNGER OUT
DOOR UNLOCKED
LATCH
ACTUATOR
ROD
LATCH
ACTUATOR
ROD
DOOR LATCH
SWITCH OPEN
SOLENOID
120 VAC
DOOR
UNLOCKED
PLUNGER IN
DOOR LOCKED
DOOR LATCH
SWITCH CLOSED
SOLENOID
120 VAC
DOOR
LOCKED
Figure 3-6A
The Door Lock Solenoid
(Door Unlocked)
Figure 3-6B
The Door Lock Solenoid
(Door Locked)
N
W
L1
BK
W
W
W
BK
BK
P4-4
R
P4-5
P3-1
P3-2
P2-1
P2-4
P4-1
BR
BU
BU
V
R
BROIL IGNITOR
BAKE IGNITOR
BAKE VALVE
BROIL VALVE
N.O.
COM
DOOR
LATCH SW.
DOOR LOCK
SOLENOID
W
GND
OVEN LT.
P3-3
P3-4
P3-6
P3-7
P2-2
P2-3/P6
GND
G
P3-5
P4-3
OVEN
TEMP
SENSOR
DOOR
SW.
OVEN CONTROL
V
V
SURFACE BURNER
IGNITION SWITCHES
SPARK MODULE
Y
Y
R
BU
BK
M
BI - METAL SW FAN N.O.
BI-METAL SW
AMBIENT N.C.
Y
Y
W
BK
BK
TRANSFORMER
OVEN LIGHT RELAY
LATCH RELAY
BROIL RELAY
BAKE RELAY