Whelen Engineering Company E-2010 Operation & Installation Manual Download Page 15

11

Menu Activation

As an alternative to Call Keys, a second
way of operating the E-2010 is to use a 4
step procedure of selecting individual
functions and addresses through the Menu
Selections and Siren Address sections of the
Keyboard.

Step 1 

involves the center portion of the

keypad, as shown. Choose from the Menu
Selections by pressing one of the four large
buttons, as previously described. The
display will show the first entry in the
selected group. Use the Up or Down arrows
to scroll through the functions, within the
selected group, stopping at the desired
function. Typically, scrolling starts with the
Down arrow.

The four large buttons are directly related to Remote Siren activation and status. The eight smaller
buttons are Setup and Configuration controls. Do not access one of the eight smaller buttons during
activation.

Step 2

 involves the right-hand portion of the keypad, as shown.

Enter the four digit address of the target remote siren. The
address is entered with the most significant bit first. The # sign
represents a “wildcard” or all values 0 to 9. ALL is a quick way
to enter four # signs, to select all sirens in the system. Press
“ENTER” to accept the screen and to continue.

Example:

To enter the address 1234, the press 1 first, 
then 2, then 3, and 4 is last. The display will 
change as shown below.

ADDR = 1???
ADDR = 12??
ADDR = 123?
ADDR = 1234

Note that entering more than four values will “bump” the address to the left. For instance, assume the
user presses the 5 key, at the end of the previous example. The address will change to 2345.

Step 3

 consists of selecting communication channel 1 or 2. The default is 1. Press “ENTER” to accept

the screen and to continue.

Step 4

, press “SEND” to make the transmission. 

This sends the command. There is no second

chance!!

MESSAGES

MENU SELECTIONS

ENTER

WARNING 

TONES

VOICE

ROTATING

DIRECTION

STATUS

PORT

SETUP

AUDIO

POLLING

SETUP

CALL

KEY

TIME

DATE

SETUP

SETUP

CALL

AUTO

SYSTEM

SETUP

OPTION

SIREN ADDRESS

2

1

3

6

5

4

9

8

7

ALL

0

#

Summary of Contents for E-2010

Page 1: ...6 7 8 9 0 ALL DOWN UP MESSAGES MENU SELECTIONS ENTER WARNING TONES VOICE ROTATING DIRECTION STATUS PORT SETUP AUDIO POLLING SETUP CALL KEY TIME DATE SETUP 2 3 4 8 7 6 5 12 11 10 9 16 15 14 13 SIREN A...

Page 2: ...f a Whelen Engineering Company Inc Model E 2010 Central Control Station Prior to reading this manual or using this product you should be familiar with Whelen Engineering Company s family of High Power...

Page 3: ...e software described in this manual is supplied with the understanding that it may not be copied or otherwise redistributed without prior permission of Whelen Engineering Company Inc All materials and...

Page 4: ...us 4 Port Setup 5 Polling Setup 5 Auto Call Setup 5 System Setup 6 Audio 6 Call Key Setup 6 Time Date 6 Option 6 Call Keys 7 Call Key Programming 7 Modify a Call Key 8 Delete a Call Key 8 Finishing a...

Page 5: ...Make a Menu Selection 2 Enter the four digit Address 3 Select the Channel 4 Press the Send button The user may select from different command control status or test functions The E 2010 supports up to...

Page 6: ...assigned a unique address In order to accept a command string the remote siren must receive the proper area code and address in the proper order in a certain time span A remote siren will reject any c...

Page 7: ...ons in the Menu Selection portion of the keyboard The wildcard address entry it equals numerical entries 0 through 9 ALL A one button method for entering four signs for selecting all remote siren addr...

Page 8: ...2 MSG 3 Activates Digital Voice Message 3 MSG 4 Activates Digital Voice Message 4 MSG 5 Activates Digital Voice Message 5 MSG 6 Activates Digital Voice Message 6 MSG 7 Activates Digital Voice Message...

Page 9: ...p for the RS 232 communication port and the Printer port The RS 232 port is dedicated to a PC operating Whelen supplied software The parameters are PRINTER ON or OFF Use the Left or Right arrow to tog...

Page 10: ...AUDIO Audio output control Use the Up or Down arrows to move through the choices The following functions are set in this section Speaker The speaker may be Off or set to Radio Channel 1 or 2 The spea...

Page 11: ...remote inputs These are described in another section Call Key 61 and Call Key 62 are available as Time of Day functions These are described in another section A Call Key in progress may be canceled b...

Page 12: ...or Right arrow to toggle the Edit Mode to ON Press ENTER A new programming screen will appear as shown The cursor is at the command prompt Use the Down arrow to scroll the cursor around to the Sequenc...

Page 13: ...a Call Key To Finish use the Down arrow to scroll through to the EDIT option Use the Left or Right arrow to select Finish and press ENTER PRINTING AN INDIVIDUAL CALL KEY Call Keys may be printed indiv...

Page 14: ...Cancel 49 Voice Message 1 09 North 15 Silent Test 01 Wail 50 Voice Message 2 10 East 63 Active Status 02 Attack 51 Voice Message 3 11 South 30 Test Clear 03 Alert 52 Voice Message 4 12 West 57 Strobe...

Page 15: ...keypad as shown Enter the four digit address of the target remote siren The address is entered with the most significant bit first The sign represents a wildcard or all values 0 to 9 ALL is a quick wa...

Page 16: ...8 lines of data This buffer is printed when the printer is reconnected or turned back on The proper way to prevent printing is to select printer Off through the Port Setup function in Menu Selections...

Page 17: ...e If desired the E 2010 can interface with a personal computer IBM compatible running Windows 95 through an RS 232 Serial Communication port Software is included to allow for the following Storing dat...

Page 18: ...only Pin Signal 1 Push To Talk Output 2 Push To Talk Output 3 Audio Out Output 4 Audio Out Output 5 Squelch In Input 6 Ground 7 Channel Grant Input 8 Audio In Input 9 Audio In Input 10 Ground 4 Make a...

Page 19: ...010 on Send the CANCEL Command to siren address 0001 While the tone is transmitting adjust the level potentiometer for 2 5 KHz deviation Repeat this step as needed to adjust the level Repeat for Chann...

Page 20: ...ot maintain time SOLUTION Check AC power and DC power pack connection Security switch is off Area code is still at 000 must be set Transmitter warm up is still 0 0 must be set to a value other than 0...

Page 21: ...C Humidity 0 95 non condensing Audio 2 wire 600 transformer balanced adjustable Control Normally open relay for Push To Talk Contact rating 1 2 A 120 VAC 1 A 24 VDC Signaling DTMF format 2 of 8 Whele...

Page 22: ......

Reviews: