background image

and switches on and off automatically (See Fig 1). Suitable for a primary  bilge pump

for boats smaller than 12 metres/39.4 ft (designed to ISO15083), or as a secondary

bilge pump on any recreational marine vessel. 

Read the following instructions carefully.

Check that the product is suitable for the intended application, follow these installation

instructions and ensure all relevant personnel read the points listed below. Also

ensure that these operating instructions are passed on to the end user.

Gulper® IC is designed for installation in recreational marine vessels only and

operated on 12 or 24 V d.c. electrical supply only. If it is intended for use for any other

purpose or with any other liquid, it is the user's responsibility to ensure that the pump

is suitable for the intended use and, in particular, that the materials are fully

compatible with the liquids to be used. The Whale Gulper® IC pump is 

not

recommended for domestic applications.

This pump 

must not 

be mounted below the water line when

connected to an intake or outlet unless the system has a 

vented loop (see Fig 1).

Not suitable for pumping flammable liquids, diesel, 

chemicals etc. Suitable for bilge water only.

NOTE

: Bilge pump capacities may not be sufficient to prevent flooding 

from rapid accumulation of water due to storms, rough weather and/ or 

rapid leaks created by hull damage and or unsafe navigational conditions. 

With all applications, it is important that a system of safe working practice 

is applied to installation, use and maintenance. Ensure the electric supply 

is turned off and waste water system is drained before installation. In order

to securely fasten the unit, ensure that the mounting surface is a minimum

thickness of 19mm (3/4") (when fitted with the screws supplied).

NOTE 

Do not screw directly to the hull - must be mounted on a bulkhead 

or on an additional board. 

NOTE - DO NOT

unscrew the rear section, as interference with the 

internal electrics will render the pump unfit for use.  - this is a non-

serviceable part of the pump. 

WARNING:

Fire hazard. Wiring must comply with applicable electrical 

standards and include a properly rated fuse or circuit breaker (See section

11v.) Improper wiring can cause a fire resulting in injury or death. Switch 

off the power while making connections. 

6. TO THE FITTER

7. APPLICATION

8. WARNINGS

5. TO THE USER

Summary of Contents for Bilge IC Series

Page 1: ...V d c BP2085B Gulper IC 24 V d c SI8284 Retail Bilge IC Remote Mounted Bilge Kit 12 V d c SI8484 Retail Bilge IC Remote Mounted Bilge Kit 24 V d c SI8222B Bulk Strainer IC and Gulper IC 12 V d c with...

Page 2: ...ge pump Suitable as a primary bilge pump for boats up to 12 metres 39 4 ft designed to ISO15083 or as a secondary bilge pump on any vessel Fig 1 Typical Installation Gulper IC as a Remote Mounted Bilg...

Page 3: ...Replacement Gulper Pump Head AK2086B Deutsch Connector Extension Cable 6m 18ft Hose Connections Gulper IC Barbed connections either 19mm or 25mm 1 Strainer IC 19mm 3 4 port Port Orientation for Strai...

Page 4: ...FIG 9 CONNECT DEUTSCH CONNECTORS FIG 10 SECURING PIPEWORK FIG 11 STRAINER IC OPERATION TEST FIG 12 FOR CLEANING DETACH TOP COVER OF STRAINER IC FIG 13 FOR CLEANING UNSCREW VALVE HOUSING IC Intelligent...

Page 5: ...vented loop see Fig 1 Not suitable for pumping flammable liquids diesel chemicals etc Suitable for bilge water only NOTE Bilge pump capacities may not be sufficient to prevent flooding from rapid acc...

Page 6: ...re installing 11 i Location Choose a position to mount the pump that is dry and away from standing water and is free from obstacles Mount in a position with the shortest possible pipe run lengths 11 i...

Page 7: ...ht connections but do not over tighten clamp rings screws hose clips Fig 3 Gulper Installation Fig 4 Fit P clamp Screw p clamp to bulkhead ensuring it is located Approx 100 mm 4 from rear housing Fig...

Page 8: ...ump is protected against reverse polarity connection the inline fuse will blow NOTE Undersized wire in the circuit before the pump will reduce voltage when the pump is under load thus giving poor perf...

Page 9: ...GULPER IC TO STRAINER IC SEE FIG 1 Connect the pre wired Deutsch connectors on Gulper IC and Whale Strainer IC Fig 9 Connect Deutsch Connectors Use 19mm 3 4 or 25mm 1 smooth bore reinforced pipework t...

Page 10: ...Checks Whale advise that the boat s plumbing system is checked annually for leaks and obstructions Also a pump electrics check is advisable Before inspecting or replacing the diaphragm disconnect the...

Page 11: ...arefully remove the lid and clean the inside walls if necessary unscrew the valve housing assembly for further cleaning Isolator switch not working not switched on Pump circuit has no power Check the...

Page 12: ...section 14 Air leak in intake line Check hose connections are airtight Open pump head and check valves and diaphragm see section 14 Punctured pump diaphragm Replace the damaged part using service kit...

Page 13: ...r States relating to electromagnetic compatibility Low Voltage Directive 73 23 EEC amended by 93 68 EEC on the harmonization of the laws of the Member States relating to electrical equipment designed...

Reviews: