background image

Suggested wiring information is given as a guide only. For full information, refer to the

USCG, ABYC and ISO regulations for marine applications and wiring gauges,

connectors and fuse protection. 

Contact Whale® Support team for further technical 44 (0)2891 270531 or

email: [email protected]

Qty 1 

Gulper® IC bilge pump

Qty 1

Strainer IC

Qty 3

No.8 self tappers and washers

Qty 1 

Inline fuse assembly

AK2050 - Service kit - Replacement head for all Gulper® pumps 

AK2086B - Deutsch® Connector Extension Cable 6m (18ft)

NOTE

:  Incorrect installation will invalidate warranty

Preparation - Always disconnect power sources before installing.

11.i Location

Choose a position to mount the pump that is dry and away from standing 

water and is free from obstacles.  

Mount in a position with the shortest possible pipe run lengths. 

11.ii Mounting Instructions - Gulper® IC

Gulper® IC can be mounted on a horizontal or vertical surface. 

When mounted vertically ensure that the pump head is lower most (see 

Fig 2).

NOTE

-It is recommended that the outlet is mounted above the water line and anti-

syphon loops are fitted where applicable- see typical installation (Fig. 1)  

When mounting, position the pump on surface and work out the best 

angles for the hose (to prevent kinking) and mark the 3 hole positions 

using the pump feet. 

NOTE:

The pump head may be rotated to suit the hose connections. 

9. PARTS LIST

10. OPTIONAL EXTRAS

11. INSTALLATION

Fig. 2 - Pump Orientation

Summary of Contents for Bilge IC Series

Page 1: ...V d c BP2085B Gulper IC 24 V d c SI8284 Retail Bilge IC Remote Mounted Bilge Kit 12 V d c SI8484 Retail Bilge IC Remote Mounted Bilge Kit 24 V d c SI8222B Bulk Strainer IC and Gulper IC 12 V d c with...

Page 2: ...ge pump Suitable as a primary bilge pump for boats up to 12 metres 39 4 ft designed to ISO15083 or as a secondary bilge pump on any vessel Fig 1 Typical Installation Gulper IC as a Remote Mounted Bilg...

Page 3: ...Replacement Gulper Pump Head AK2086B Deutsch Connector Extension Cable 6m 18ft Hose Connections Gulper IC Barbed connections either 19mm or 25mm 1 Strainer IC 19mm 3 4 port Port Orientation for Strai...

Page 4: ...FIG 9 CONNECT DEUTSCH CONNECTORS FIG 10 SECURING PIPEWORK FIG 11 STRAINER IC OPERATION TEST FIG 12 FOR CLEANING DETACH TOP COVER OF STRAINER IC FIG 13 FOR CLEANING UNSCREW VALVE HOUSING IC Intelligent...

Page 5: ...vented loop see Fig 1 Not suitable for pumping flammable liquids diesel chemicals etc Suitable for bilge water only NOTE Bilge pump capacities may not be sufficient to prevent flooding from rapid acc...

Page 6: ...re installing 11 i Location Choose a position to mount the pump that is dry and away from standing water and is free from obstacles Mount in a position with the shortest possible pipe run lengths 11 i...

Page 7: ...ht connections but do not over tighten clamp rings screws hose clips Fig 3 Gulper Installation Fig 4 Fit P clamp Screw p clamp to bulkhead ensuring it is located Approx 100 mm 4 from rear housing Fig...

Page 8: ...ump is protected against reverse polarity connection the inline fuse will blow NOTE Undersized wire in the circuit before the pump will reduce voltage when the pump is under load thus giving poor perf...

Page 9: ...GULPER IC TO STRAINER IC SEE FIG 1 Connect the pre wired Deutsch connectors on Gulper IC and Whale Strainer IC Fig 9 Connect Deutsch Connectors Use 19mm 3 4 or 25mm 1 smooth bore reinforced pipework t...

Page 10: ...Checks Whale advise that the boat s plumbing system is checked annually for leaks and obstructions Also a pump electrics check is advisable Before inspecting or replacing the diaphragm disconnect the...

Page 11: ...arefully remove the lid and clean the inside walls if necessary unscrew the valve housing assembly for further cleaning Isolator switch not working not switched on Pump circuit has no power Check the...

Page 12: ...section 14 Air leak in intake line Check hose connections are airtight Open pump head and check valves and diaphragm see section 14 Punctured pump diaphragm Replace the damaged part using service kit...

Page 13: ...r States relating to electromagnetic compatibility Low Voltage Directive 73 23 EEC amended by 93 68 EEC on the harmonization of the laws of the Member States relating to electrical equipment designed...

Reviews: