background image

Note

- Output capacity depends on installation and operating conditions.

Whale's policy is one of continuous improvement and we reserve the right to change

specifications without prior notice.

2. SPECIFICATION

Model

Bilge IC bilge water kit

Product Code

BP2083B SI8284  SI8222B SI8224B BP2085B SI8484 SI8422B SI8424B

Cable Length

/

4m

(12ft)

2m

(6ft)

4m

(12ft)

/

4m

(12ft)

2m

(6ft)

4m

(12ft)

Voltage

12V d.c.

24V d.c.

Voltage Range

10 v d.c. to 13.6 V d.c.

21.6 V d.c. to 27.2 V d.c

Current  Profile

Soft  start /  soft stop

Recommenced Fuse 

Size

10 Amp Automotive

5 Amp Automotive

Minimum Wire Size

1.5mm

²

(16 AWG)

Weight

2.6 kg (5.7 lbs)

Materials

Pump head

- Glass filled Nylon. 

Valves and Diaphragm

- Santoprene®

Pump Body

- Aluminium. 

Gear Whee

l - Delrin®

Fasteners

- Stainless Steel

Service Kits /

Accessories

AK2050 - Replacement Gulper® Pump Head

AK2086B - Deutsch Connector Extension Cable 6m (18ft)

Hose Connections

Gulper® IC - Barbed connections - either 19mm (¾") or  25mm (1")

Strainer IC - 19mm (3/4") port

Port Orientation for   

Strainer IC

Horizontal (easily changed to vertical / side)

Maximum Suction Lift 

(Vertical)

3m (10 ft)

Maximum Discharge 

Head (Vertical)

3m (10 ft)

Maximum Discharge 

Head and Suction Lift 

Combined 

(vertical vent)

4m (13.5 ft)

Operational Time    

Delays

1 second on delay / 45 second off delay

Current Draw On

Standby

Low power 0.01 Amps supply

PERFORMANCE DATA 

Suction Lift

0m / 0ft

0m / 0ft

1m / 3ft

1m / 3ft

Discharge Head

1m / 3ft

1m / 3ft

1m / 3ft

1m / 3ft

Hose Size

19mm / ¾"

25mm/ 1"

19mm / ¾"

25mm/ 1"

Flow Rate per min

19 ltrs 

(5 US gals)

17.5 ltrs 

(4.6 US gals)

17.5 ltrs 

(4.6 US gals)

15.5 ltrs

(4.1 US gals)

Flow Rate per hour

1140 ltrs

(300 US gals)

1050 ltrs

(276 US gals)

1038 ltrs

(270 US gals)

930 Ltrs

(246 US gals)

Current Draw (12 V d.c.) 

7.5 amps

8 amps

7.5 amps

8 amps

Current Draw (24 V d.c.) 

3.25 amps

4 amps

3.25 amps

4 amps

Summary of Contents for Bilge IC Series

Page 1: ...V d c BP2085B Gulper IC 24 V d c SI8284 Retail Bilge IC Remote Mounted Bilge Kit 12 V d c SI8484 Retail Bilge IC Remote Mounted Bilge Kit 24 V d c SI8222B Bulk Strainer IC and Gulper IC 12 V d c with...

Page 2: ...ge pump Suitable as a primary bilge pump for boats up to 12 metres 39 4 ft designed to ISO15083 or as a secondary bilge pump on any vessel Fig 1 Typical Installation Gulper IC as a Remote Mounted Bilg...

Page 3: ...Replacement Gulper Pump Head AK2086B Deutsch Connector Extension Cable 6m 18ft Hose Connections Gulper IC Barbed connections either 19mm or 25mm 1 Strainer IC 19mm 3 4 port Port Orientation for Strai...

Page 4: ...FIG 9 CONNECT DEUTSCH CONNECTORS FIG 10 SECURING PIPEWORK FIG 11 STRAINER IC OPERATION TEST FIG 12 FOR CLEANING DETACH TOP COVER OF STRAINER IC FIG 13 FOR CLEANING UNSCREW VALVE HOUSING IC Intelligent...

Page 5: ...vented loop see Fig 1 Not suitable for pumping flammable liquids diesel chemicals etc Suitable for bilge water only NOTE Bilge pump capacities may not be sufficient to prevent flooding from rapid acc...

Page 6: ...re installing 11 i Location Choose a position to mount the pump that is dry and away from standing water and is free from obstacles Mount in a position with the shortest possible pipe run lengths 11 i...

Page 7: ...ht connections but do not over tighten clamp rings screws hose clips Fig 3 Gulper Installation Fig 4 Fit P clamp Screw p clamp to bulkhead ensuring it is located Approx 100 mm 4 from rear housing Fig...

Page 8: ...ump is protected against reverse polarity connection the inline fuse will blow NOTE Undersized wire in the circuit before the pump will reduce voltage when the pump is under load thus giving poor perf...

Page 9: ...GULPER IC TO STRAINER IC SEE FIG 1 Connect the pre wired Deutsch connectors on Gulper IC and Whale Strainer IC Fig 9 Connect Deutsch Connectors Use 19mm 3 4 or 25mm 1 smooth bore reinforced pipework t...

Page 10: ...Checks Whale advise that the boat s plumbing system is checked annually for leaks and obstructions Also a pump electrics check is advisable Before inspecting or replacing the diaphragm disconnect the...

Page 11: ...arefully remove the lid and clean the inside walls if necessary unscrew the valve housing assembly for further cleaning Isolator switch not working not switched on Pump circuit has no power Check the...

Page 12: ...section 14 Air leak in intake line Check hose connections are airtight Open pump head and check valves and diaphragm see section 14 Punctured pump diaphragm Replace the damaged part using service kit...

Page 13: ...r States relating to electromagnetic compatibility Low Voltage Directive 73 23 EEC amended by 93 68 EEC on the harmonization of the laws of the Member States relating to electrical equipment designed...