background image

1.

TYPICAL INSTALLATION

12. PLUMBING

2.

SPECIFICATION 

13. INSTRUCTIONS FOR USE

3.

CONTENTS AND DIAGRAMS

14. MAINTENANCE  

4.

PRINCIPLES OF OPERATION 

15. HELPFUL HINTS 

5.

TO THE USER

16. TROUBLE SHOOTING

6.

TO THE FITTER 

17. WINTERIZING 

7.

APPLICATION  

18. SERVICE SUPPORT DETAILS

8.

WARNINGS 

19. PATENTS/ TRADEMARKS  

9.

PARTS LIST

20. WARRANTY STATEMENT

10. OPTIONAL EXTRAS

21. EU DECLARATION OF 

11. INSTALLATION 

CONFORMITY, APPROVALS 

LIST OF DIAGRAMS: 

FIG 1

GULPER® IC - TYPICAL INSTALLATION AS A REMOTE MOUNTING 

BILGE PUMP FOR USE WITH WHALE STRAINER IC 

FIG 2

PUMP ORIENTATION

FIG 3

GULPER® IC INSTALLATION 

FIG 4

INSTALL P CLAMP 

FIG 5

STRAINER IC CONNECTION

FIG 6

STRAINER IC CONNECTION

FIG 7

WIRING GULPER® IC TO STRAINER IC    

FIG 8

CONNECTING SWITCHING CABLE THROUGH BULKHEAD 

FIG 9

CONNECT DEUTSCH® CONNECTORS

FIG 10

SECURING PIPEWORK

FIG 11

STRAINER IC OPERATION TEST 

FIG 12 

FOR CLEANING - DETACH TOP COVER OF STRAINER IC  

FIG 13 

FOR CLEANING - UNSCREW VALVE HOUSING

IC - Intelligent Control Technology

At the heart of every Whale® IC product lies innovative electronic control circuitry built

in. This enables IC sensor accessories to communicate directly with IC pumps to

control their performance. These accessories send signals to built-in intelligent

software which then control the pumps to react as required.

Gulper® IC

The Gulper® IC fully automatic self-priming pump is designed as a remote mounting

bilge pump. Output capacity depends on installation and operating conditions.

REMOTE MOUNTED BILGE APPLICATION

Save time and money by reducing four separate components to one pre-wired

system. Remote mounting automatic Gulper® IC receives signals from Strainer IC 

3. LIST OF CONTENTS AND LIST OF DIAGRAMS

4. PRINCIPALS OF OPERATION

Summary of Contents for Bilge IC Series

Page 1: ...V d c BP2085B Gulper IC 24 V d c SI8284 Retail Bilge IC Remote Mounted Bilge Kit 12 V d c SI8484 Retail Bilge IC Remote Mounted Bilge Kit 24 V d c SI8222B Bulk Strainer IC and Gulper IC 12 V d c with...

Page 2: ...ge pump Suitable as a primary bilge pump for boats up to 12 metres 39 4 ft designed to ISO15083 or as a secondary bilge pump on any vessel Fig 1 Typical Installation Gulper IC as a Remote Mounted Bilg...

Page 3: ...Replacement Gulper Pump Head AK2086B Deutsch Connector Extension Cable 6m 18ft Hose Connections Gulper IC Barbed connections either 19mm or 25mm 1 Strainer IC 19mm 3 4 port Port Orientation for Strai...

Page 4: ...FIG 9 CONNECT DEUTSCH CONNECTORS FIG 10 SECURING PIPEWORK FIG 11 STRAINER IC OPERATION TEST FIG 12 FOR CLEANING DETACH TOP COVER OF STRAINER IC FIG 13 FOR CLEANING UNSCREW VALVE HOUSING IC Intelligent...

Page 5: ...vented loop see Fig 1 Not suitable for pumping flammable liquids diesel chemicals etc Suitable for bilge water only NOTE Bilge pump capacities may not be sufficient to prevent flooding from rapid acc...

Page 6: ...re installing 11 i Location Choose a position to mount the pump that is dry and away from standing water and is free from obstacles Mount in a position with the shortest possible pipe run lengths 11 i...

Page 7: ...ht connections but do not over tighten clamp rings screws hose clips Fig 3 Gulper Installation Fig 4 Fit P clamp Screw p clamp to bulkhead ensuring it is located Approx 100 mm 4 from rear housing Fig...

Page 8: ...ump is protected against reverse polarity connection the inline fuse will blow NOTE Undersized wire in the circuit before the pump will reduce voltage when the pump is under load thus giving poor perf...

Page 9: ...GULPER IC TO STRAINER IC SEE FIG 1 Connect the pre wired Deutsch connectors on Gulper IC and Whale Strainer IC Fig 9 Connect Deutsch Connectors Use 19mm 3 4 or 25mm 1 smooth bore reinforced pipework t...

Page 10: ...Checks Whale advise that the boat s plumbing system is checked annually for leaks and obstructions Also a pump electrics check is advisable Before inspecting or replacing the diaphragm disconnect the...

Page 11: ...arefully remove the lid and clean the inside walls if necessary unscrew the valve housing assembly for further cleaning Isolator switch not working not switched on Pump circuit has no power Check the...

Page 12: ...section 14 Air leak in intake line Check hose connections are airtight Open pump head and check valves and diaphragm see section 14 Punctured pump diaphragm Replace the damaged part using service kit...

Page 13: ...r States relating to electromagnetic compatibility Low Voltage Directive 73 23 EEC amended by 93 68 EEC on the harmonization of the laws of the Member States relating to electrical equipment designed...