Cleaning
Bilge IC should be wiped clean regularly to maintain optimal performance and ensure
no clogging occurs. See Fig 12 and Fig 13 for cleaning Strainer IC.
WARNING:
Do not use abrasive cleaners.
Fig 12 For Cleaning - Detach Top Cover
Fig 13 For Cleaning - Unscrew
of Strainer IC
Valve Housing
The unique ezi-clamp ring makes installation and maintenance of the pump easier
with a retaining screw which means the head can be fitted or replaced easily by one
fitter, without the risk of dropping screws.
15. HELPFUL HINTS
16. TROUBLESHOOTING
PROBLEM
POSSIBLE CAUSES
POTENTIAL SOLUTION
Gulper IC fails
to operate
The Strainer IC may need
cleaned.
Blockage in valve housing
Unclip the top cover of the Strainer IC, clean and
inspect for debris (Fig 5). Carefully remove the lid
and clean the inside walls, if necessary unscrew the
valve housing assembly for further cleaning.
Isolator switch not working /
not switched on.
Pump circuit has no power.
Check the isolator switch is on and working.
Check electrical connections to ensure pump is
receiving power as normal and free from corrosion.
Check power supply.
Main power (Isolator switch)
supply OFF /not working.
Loose wiring connection
Check the isolator switch is on.
Pump circuit has no
power
Check electrical connections to ensure pump is
receiving power as normal and free from corrosion.
Check there is 12/24 volts from the battery
Fuse blown or loose
electrical connection
Check the in-line fuse & ensure all electrical
connections are tight and free from corrosion. If fuse
has blown, check for reverse polarity, closed valves
or seacocks, then for debris in pump head and clean
out if necessary (refer to installation section).
Replace fuse and run pump.