Machine control board, Software
704 67 020 00 _ 111
GF Robimat XL / XM
OPERATING INSTRUCTIONS
[INSTALLING MODE] M7 > [READOUT]
[IRDA max. RATE]
IRDA = Infrared-interface
[19,200] (default)
Infrared-interface (IRDA) data transfer rate is between 19,200 Bit/s and 57,600 Bit/s. The
display installed as standard has a data transfer rate of 19,200 Bit/s.
[CGW REPORTS]
[no] (default)
Is only necessary if online modules compatible to "Verbose" are to be installed. Sielaff uses
the FTL mode for data transfer which includes additional information to NAMA standard
Verbose.
[INTERVAL DT. CTL.]
only for EVA-DTS 6.1 Standard
[auto]
Once the statistics have been downloaded, they are deleted when the next vend is made (as
before).
[save]
The statistics are not deleted after downloading. Deletion must be started via IR.
[INTERVAL EV.CTL.]
only for EVA-DTS 6.1 Standard
[auto]
The errors are deleted once they have been read out and when the next vend is made (as
before).
[save]
The errors are not deleted after having been read out; deletion must be started via IR.
[DTS data select]
Fields can be switched on and off individually. The definition of the fields is described in the
EVA-DTS specification.
Fields: PA2 - PA3 - PA4 - PA5 - PA6 - PA7 - PA8
[on]
Transfer is enabled.
[off]
Transfer of corresponding fields (e.g. PA8) is inhibited.
[EXT. SERIAL 5.2]
Programme machine data read out function.
[HMI]
Read out using HMI-protocol
[READ OUT]
Read out using downloading devices.
[EXT.READOUT PROT]
External readout possibility using corresponding equipment.
[DDCMP]
Readout using DDCMP