Machine control board, Software
704 67 020 00 _ 111
OPERATING INSTRUCTIONS
GF Robimat XL / XM
6.4.8.3 [DOWNLOAD]
[INSTALLING MODE] M7 > [READOUT]
[PROTOCOL (1)]
[EVA-DTS] (default)
Data transfer protocol between vending machine controller and payment system.
[DEX/UCS]
This protocol is only required if a display with DEX/UCS interface is connected.
[EVA-DTS VERSION]
[6.0 (5.x, 4.x)]
Programming EVA-DTS Version.
[6.1 or newer]
This version contains additional information. It is required for future applications.
[IRDA Adapter]
IRDA = Infrared-interface
[Cable]
This setting is necessary if, for example, a DEX/UCS interface can be connected to the display
and EVA-DTS data is to be read out from it.
[IRDA]
This is the standard setting and means that EVA-DTS data can be read out via the integrated
IRDA interface.
[EVA-DTS SEL.No.
]
You can determine how the selection numbers are reported to MDB here and in EVA-DTS.
This setting has no effect on machines with selection numbers starting with 1.
[starts with] 1 (default) The lowest selection number in the machine is 1.
[starts with] 10
The number being transmitted, is the one shown as the selection number on the display.
CHECK
←L SEL. M→ :E
M
7
INSTALLING MODE
←L SEL. M→ :E
INSTALLING MODE
> MACHINE
PROTOCOL(1)
EVA-DTS
EVA/DTS VERSION
6.0(5.0x,4.x)
IRDA max.RATE
19200
INSTALLING MODE
> READOUT
USE VERBOSE CGW
no
DTS data select
PA2
on
INTERVAL EV.CTL.
auto
E
L
E
L
E
L
E
L
E
L
E
L
2xM
INTERVAL DT.CTL.
auto
IRDA Adapter
integrated(IRDA)
E
L
E
L
EVA/DTS SEL. No.
starts with 1
E
L
E
L
EXT. SERIAL 5.2
HMI
EXT.READOUT PROT
DDCMP