![Westinghouse WGRGH**199 Series Installation, Start-Up, Maintenance, Parts, Warranty Download Page 44](http://html1.mh-extra.com/html/westinghouse/wgrgh-199-series/wgrgh-199-series_installation-start-up-maintenance-parts-warranty_965799044.webp)
44
WHL-060 REV. 1.6.16
CONNECTOR
DESCRIPTION
HT SELV
NO. OF LOCATION
PIN
BOARD SILK
CN7
LWD1140-14
1
F.S
Flame Sensor
SELV (5V)
8
2
OP.S
Operating Water Temperature Sensor
9
3
DH.S
DHW Temperature Sensor
10
4
I.S
Inlet Water Temperature Sensor
11
5
BG.S
Exhaust Temperature Sensor
12
6
ST.S
Return Water Temperature Sensor
13
7
SP.S
Overheat Temperature Sensor
14
CN10
SMW250-08D
1
IWM
(Flow Control
Valve)
IWM Stepper Motor Coil / Y Phase
SELV (14V)
2
3
IWM Stepper Motor Coil / X Phase
4
5
GND
6
IWM Stepper Motor Position
7
VDD
8
CN14
SMW250-09D
1
DHM
(Mixing Valve)
GND
2
DHM Stepper Motor Position
3
VDD
4
DHM Stepper Motor Coil X Phase
5
DHM Stepper Motor Coil Y Phase
6
VDD
7
DHM Stepper Motor Coil X Phase
8
DHM Stepper Motor Coil Y Phase
9
Unused
-
CN3
SMW250-06D
1
APS Sensor
VCC
SELV (5V)
2
GND
3
Voltage Input
4
FLUX1
VCC
5
Water Flow Sensor
6
GND
Table 22
– Water Heater Wiring 2