4. Management
4.7 Zoning
length=96 (0x60) Peripheral device type: enclosure services device
Vendor identification: HGST
Product identification: H4102-J
Product revision level: 2050
Unit serial number: USWSJ02819EZ0012
C:\> sg_inq SCSI3:1,29,0
standard INQUIRY:
PQual=0 Device_type=13 RMB=0 LU_CONG=0 version=0x06 [SPC-4]
[AERC=0] [TrmTsk=0] NormACA=0 HiSUP=0 Resp_data_format=2
SCCS=0 ACC=0 TPGS=0 3PC=0 Protect=0 [BQue=0]
EncServ=1 MultiP=0 [MChngr=0] [ACKREQQ=0] Addr16=0
[RelAdr=0] WBus16=0 Sync=0 [Linked=0] [TranDis=0] CmdQue=1
[SPI: Clocking=0x0 QAS=0 IUS=0]
length=96 (0x60) Peripheral device type: enclosure services device
Vendor identification: HGST
Product identification: H4102-J
Product revision level: 2050
Unit serial number: USWSJ02819EZ0012
If multiple serial numbers are identified, the numbers can then be matched to their
corresponding physical enclosures to determine which is the correct one for zoning.
Note:
If multiple devices share a serial number, the devices represent either
multiple HBAs within the host or multiple IOMs within the enclosure. In either
situation, any of the listed device paths can be used to send the binary
zoning configuration file to the enclosure.
Step 3 :
Use the
sg_ses_microcode
utility to send the binary zoning configuration file to the enclosure
using any of the IOM SEP handles:
C:\> sg_ses_microcode SCSI3:0,84,0 -m0xe -N -b 4096 -I H4102-
J_Zoning_17x1_Config.bin
Note:
In this example, the binary file for configuration 1 is being used. For
more information about this and other predefined zoning configurations, see
Predefined Zoning Configurations
.
Step 4 :
Use the
sg_ses_microcode
utility to activate the zoning configuration file:
C:\> sg_ses_microcode SCSI3:0,84,0 -m0xf
After the file is activated, the SAS connectors will be cycled off and on, triggering the host to
perform discovery.
Note:
The file-based zoning feature and the specified zoning configuration are now
enabled. The remaining steps in this task are for verification purposes and require the
WDDCS Tool. For instructions on enabling file-based zoning using
only
the WDDCS Tool,
please see the
WDDCS Tool User Guide
.
Step 5 :
Use the WDDCS Tool's
show
command to view the SEP device handles:
C:\> wddcs show
248