V3.8
OnTime Industrial Ethernet
U/R/T200 series Installation Guide
- 26 -
OnTimenet/switch/fs200/stat/statTrapEnable.
The switch sends a SNMP TRAP :
* when the ring functions is not working
* when it starts to work again,
* when the GPS is out of sync
* when the GPS is in sync state.
* when a monitored link is down (see the IP Configuration tool).
•
Frntv1
trap
To enable the frntv1 warning system - use
OnTimenet/switch/fs200/frntv1/frntEnTrapPrim trap or the
OnTimenet/switch/fs200/frntv1/frntEnTrapSec. The switch sends a SNMP
TRAP when the frntv1 has lost the connection to the backbone ring.
•
Temperature
Alarm
Trap
To enabled the monitoring of the temperature in the switch - use the
tempAlarm trap. OnTimenet/switch/fs200/tempAlarm/tempTrapEn. The switch
sends a SNMP TRAP when the temperature has raised the predefined limit.
The Trap host address is set by the Westermo OnTime private Management Information
Base
(
MIB) general part.
See the Operational Manual for further information about SNMP and SNMP traps.
The private MIB is available for download from OnTime web page:
http://www.OnTimenet.com/upgrade.htm
or the CD. This MIB can be imported in the users
Network Management Tool. See the documentation for your Network Management Tool for
how to import and how to use a private MIB.
4.5 DHCP
The R/T200 switch supports Dynamic Host Configuration Protocol (DHCP). The R/T200
switch can get an IP address dynamically from a DHCP server. To enable/disable DHCP tick
the DHCP box and press the ‘Set’ button. Press the ‘Reset’ button to restart the Switch with
DHCP enabled/disabled. The “IP address” found in the IP field of the “Selected device” dialog
has no meaning if the DHCP box is enabled.
4.6 Static IP address
A static IP address can be set on the R/T200 switch by entering an available IP address in the
“IP address” field and the corresponding IP subnet mask of your IP domain in the “Subnet
mask” in the “Selected device” dialog. Your new IP address and mask will take immediate
effect after you have pressed the ‘Set’ button. No switch restart is required for this operation.
A correct IP address and IP mask must be set in order for correct operation of ping, SNMP
and other IP based applications on the R/T200.