5. Run the cursor over the listed Switch and click the mouse to select it.
6. A new configuration Window will open:
7. If required; assign a new IP address and Subnet address for this Switch.
8. Press the ‘Set’ button to assign this IP address and Subnet settings to the Switch.
9. Tick the ‘Enable FRNT Ring’ and ‘Network focal point’ to set the Switch to be the
Focal Point and Bus Member to ensure the Switch configured to run within a
Redundant Ring.
10. Press the ‘Set’ button (all your changes performed will be set).
11. Press the ‘Restart’ button to re-configure the Switch. The Switch will run through the
start sequence. During this period communication to the Switch will be lost.
12. Connect the next Switch into the ring. (This must be connected from Port 8 to Port 7
in a clockwise manner on version 2.30 or older).
13. Press the ‘Scan for devices’ button. The second Switch will appear on the list.
14. Run the cursor over the second Switch and left click the mouse.
15. If required; assign a new IP address and Subnet address for this Switch.
16. Tick ‘Enable FRNT ring’ to ensure the Switch is configured to run within a Redundant
Ring.
17. Press the ‘Set’ button.
18. Press the ‘Restart’ button to re-configure the Switch. The Switch will run through the
start sequence. During this period communication to the Switch will be lost.
19. Continue connecting Switches in this manner until the ring has been completed