49
6623-3201
To configure
CSD Multiplexed mode
complete the following steps:
1. Select the
Wireless
tab from the main menu and then select
Circuit switched mode
tab from the sub-menu.
2. Set the Operating mode to
Multiplexed
and click
Update
.
Click the
Edit icon
for desired port.
3. In the section titled
Multiplexed Mode Configuration
:
Set the Menu visibility to either
•
Silent
or
Verbose
.
Set the
•
Disconnect character
in hex, leave it blank for
no disconnect character. This value is specified in
hex so that it is not limited to text values.
Set the
•
Disconnect guard
time in seconds.
Set the
•
Default port
to use should a port select com-
mand not be received.
Set the number
•
Bytes to wait from connection until the
default port selected
.
Set the number of
•
Seconds to wait from connection
until default port selected
.
4. The second configuration section allows the parameters
for each port to be set up. Each port can act in one of two
modes:
(a) Raw mode:
The port will be inactive except when
selected during a CSD call. Data will pass transparently
through the multiplexer. This is suited to communicating
with devices that do not expect to see an AT command
interface.
(b) Unit mode:
The port provides an AT command
interface. A device attached to the port will see a simu-
lated AT command interface that will indicate when a call
is incoming and allow the port to initiate dialing of a CSD
call. The is suited to devices that expect to see a dial-up
type interface.
5. Click the
Update
button to save the changes.
Summary of Contents for MRD-310
Page 11: ...11 6623 3201 Figure 9 Status alarm page ...
Page 51: ...51 6623 3201 Figure 43 SMS Triggers configuration page ...
Page 55: ...55 6623 3201 Figure 46 SMS Triggers number to accept added ...
Page 125: ...125 6623 3201 Figure 93 IPsec Phase 2 configuration ...
Page 137: ...137 6623 3201 Figure 100 IPsec connection status Figure 101 IPsec connection status detail ...