SiteVu Main Menu 

Communication Settings Menu (1)

Log Viewer (2)

SiteVu Service Port/Telnet Menus Reference

Digital Inputs (3)

Ethernet Settings Menu (1)

SNMP Settings Menu (2)

NTP Settings Menu (3)

Telnet Settings Menu (4)

Analog Inputs (4)

Ethernet Remote IP Address (1)
Ethernet Gateway IP Address (2)
Ethernet Subnet Mask (3)

Allow SNMP Read (1)
SNMP Read Community (2)
Trap Recipient 1 (3)
Trap Recip 1 IP Address (4)
Trap Recip 1 Community (5)
Trap Recip1 Send Current alarms (6)
Trap Recipient 2 (7)
Trap Recip 2 IP Address (8)
Trap Recip 2 Community (9)

Trap Recip 2 Send Current alarms (10)
SNMP Keepalive Trap (11)
SNMP Keepalive Trap Time Interval (12)

Use a NTP time server (1)
Time Server IP Address (2)
NTP polling time (3)

Telnet (terminal over TCP/IP) (1)
Telnet Server Port (2)

Sensor 1-4 Configuration (1-4)

Sensor Name (1)
Enable Alarm (2)
Hysteresis (seconds) (3)

Alarm when input is (4)
Severity (5)
Send SNMP Trap (6)
Normal Condition Name (7)
Alarm Condition Name (8)

Digital Output Number (9)
Output State on Alarm (10)
Sensor Description (11)

Sensor 1-7 Configuration (1-7)

Sensor Name(1)
Range (2)
Multiplier (3)
Offset (4)
Units (5)

Low Alarm (enable 6)

Digital Output (5)

Send SNMP Trap (Low 7)
Low Alarm Point (8)

Return Point (Low 9)

Severity (Low 10)

Digital Output Number (Low 11)

Output State on Alarm (Low 12)

High Alarm (enable 13)

Send SNMP Trap (High 14)
High Alarm Point (15)

Return Point (High 16)
Severity (High 17)

Digital Output Number (High 18)

Output State on Alarm (High (19)

Sensor Description (20)

Sensor Name (1)

Current State (2)

Controlling Input (3)

Sensor Description (4)

Current Alarms (6)

Telnet Inactivity Timeout (3)

© Noran Tel, Inc

Rev. 0806-41A  Firmware v1.0.X

Security (7)

User 1-5 Identities (1-5) 

Security Log (6)

ACL List (7)

Login Name (1)
Security Access (2)
Communication Access (3)

System Properties Access (4)

Analog Input Access (5)
Digital Input Access (6)

Digital Output Access (7)

File Transfer Access (8)

Use Access Control List (1)

(1-50 Allowable IP Addresses (2-51))

Pass-Through Port Access (9)

Security Lockout Time (8)

Security Lockout Message (9)

Remove all Security Lockouts (10)

Log Purge Access: (10)

System Properties (10)

LCD Properties (1)

Current time (2)

Daylight Savings (5)

LCD Screen Saver (1)

Screen Saver cycle time (2)

1-5 Display Sensors (3-7)

System Information (9)

RUID (1) 
MAC (2)

Version (3)
Remote Name (4)
Current Time (5)

Time Zone Name (3)

Time Zone offset from UTC (4)

File Transfer Menu (TFTP) (8)

TFTP (1)
TFTP IP listening port (2)

Config file 1 (3)
Config file 2  (4)
Config file 3 (5)
Firmware upgrade file (6)
Log File (7)

Security log file (8)

Remote Name (syslocation) (8)

DST Start (6)

DST End (7)

Battery Rundown Menu (11)

Enable Rundown Test (1) 

File Name (1)
Delete File (2)

Rundown Fullstring Input (2) 
Rundown Fullstring Trigger Voltage (3) 

Rundown Files (4-7) 

 

Summary of Contents for Noran Tel SITE VU MINI N04005-SVU/L0806

Page 1: ...emote units using the local port service port via USB and or using the Telnet option over Ethernet Any VT100 compatible Telnet client software and serial communication software may be used to communic...

Page 2: ...n is dropped The user must wait a set amount of time Security Lock Out time before trying to reconnect via Telnet After a successful login the Site Vu Main Menu is displayed If 3 failed logins occur f...

Page 3: ...5 DIGITAL OUTPUTS 5 9 6 CURRENT ALARMS 6 9 7 SECURITY 7 10 7 1 USER PROPERTIES MENU 1 5 10 7 2 SECURITY LOG MENU 6 10 7 3 ACCESS CONTROL LIST MENU 7 11 7 4 SECURITY LOCKOUT MENU ITEMS 8 10 11 8 FILE T...

Page 4: ...item that contains a colon and presses the Enter key the menu item selected is displayed along with its previous setting Also a prompt is displayed for the user to enter a new value for the setting Th...

Page 5: ...nit to send SNMP v1 traps to Network Management Station s Figure 1 3 displays the menu item settings for this menu Figure 1 3 SNMP Settings Menu The Allow SNMP Read menu item can be enabled to allow a...

Page 6: ...ge the default port for the Telnet server A user may want to change this port for access through firewalls and or to obfuscate the location of the Telnet server on the SiteVu remote unit The Telnet In...

Page 7: ...to add a de bounce time to eliminate jitter on the sensor This value can be anywhere between 1 10th of a second to 6553 1 seconds 109 minutes Refer to the Digital Input sensor section in the hardware...

Page 8: ...outputs a voltage between 0 50mV Rather than displaying a voltage and using alarm points in the mV range the value can be converted to Amperes instead o Multiplier 400A 50mV 8000 o Range 0 125mV o Of...

Page 9: ...ensor is controlled by an alarm event When AUTO is set the state of the relay SET or CLEAR is displayed after the AUTO setting When the digital output changes state a SNMP trap is automatically sent a...

Page 10: ...ACCESS READ ACCESS or READ WRITE ACCESS The read privilege allows that user to view all the menus in that section The read and write access privilege allows a user to read the menus and change the con...

Page 11: ...hat are currently locked Also a failed login Security Log item is created in the Security log menu item A username becomes locked if the user tries to login with the correct username but not the corre...

Page 12: ...tings 6 The firmware in the SiteVu can be updated remotely using the menu options available in Figure 8 3 Figure 8 3 Firmware File Settings Menu The Enable File Transfer menu item allows the user to e...

Page 13: ...cessed through this menu Figure 10 1 System Properties Menu The Current time item allows a user to set the time for the remote unit The time entered is based on the Time Zone offset from UTC menu item...

Page 14: ...t regular intervals and store the results in a tab separated value file tsv Initially data is logged every second After the first 5 minutes it is logged less frequently at 1 minute intervals The Site...

Page 15: ...puts it on the user s computer The first two steps essentially copies the configuration from one SiteVu remote unit and places that same configuration on the second remote unit Downloading with XMODE...

Page 16: ...tput Number Low 11 Output State on Alarm Low 12 High Alarm enable 13 Send SNMP Trap High 14 High Alarm Point 15 Return Point High 16 Severity High 17 Digital Output Number High 18 Output State on Alar...