33
West Mountain Radio
Operating Manual
/title
title
When using /test for hands-free test and sav-
ing results to a file specified by /open, this
option sets the title of this set of data when ap-
pending to the file. This parameter is optional.
If user does not specify a title, software will
use “TEST”. If title is already used in speci-
fied file, test name will be appended with an
incremental number (ex. “TEST 2” will become
“TEST 3”).
Example:
/test discharge 1 /open test.bt2 /title “Test
XRF200”
/temperature
n
n specifies the temperature in Celsius to stop
the test, to prevent test from running if external
temperature is too high.
All tests support stopping at the specified
temperature (n) however, not all tests sup-
port temperature graphing. Temperature will
be graphed if the selected test supports it and
saved to file (/open)
/termperatureF
n
n specifies the temperature in Fahrenheit to
stop the test, to prevent test from running if
external temperature is too high.
All tests support stopping at the specified
temperature (n) however, not all tests sup-
port temperature graphing. Temperature will
be graphed if the selected test supports it and
saved to file (/open).
/graph
AmpHrs
WattHrs
Minutes
Ragone
Amps
Watts
If performing a hands-free test (/test), this
specifies the graphing format to be used. Ra
-
gone graphing only works for discharge tests.
Amps and Watts are only available for Power-
Profile tests
/amplifiers
n
For a hands-free test, specifies the number of
CBA Amplifiers connected to the system. If
this is not specified, it is assumed 0.
/unit
Serial
For multiple CBA operation, this is an optional
argument to specify which CBA to use.
Example:
/unit 40100
/chargeunit
Serial
For multiple Charger Interfaces this is an
optional argument to specify which Charger
Interface to use