
User manual - English
User-manual-BlueLine-v.02
01/2021
51
600 mm
150 mm
150 mm
150 mm
2
Abb. 5.2.a: Back view L-model
1
3
Air space
50 mm
Fig. 5.2.b: Installation instructions for
hygienic drainage of residual water
Outlet
hose (DN
20)
(4) Discharge
Funnel with
siphon
5.2 Installation air-cooled units (version L)
To ensure safe operation, in air-cooled units a minimum distance to walls on all sides and at the top has
to be adhered to (see Fig. 5.2.a).
The warm air generated in air-cooled units must be able to escape upwards without obstruction, because
otherwise there is a risk of an air short circuit.
IMPORTANT:
If an air-cooled ice cube maker is installed in a small, enclosed room, it is important to ensure
adequate air circulation (fresh air supply).
Please connect the enclosed inlet hose (DN 8; ¾”–screwing) with the water inlet (2) and with the
water tab (cold water-/ fresh water inlet).Make sure that the rubber sealing is well in place.
Please connect the enclosed outlet hose (DN 20) with the residual water outlet (3), then run the
water drain tube to the waste water system.
Ensure that the tube has a continuous gradient and no
bends.
Without adequate gradient of the drain tube, the storage container may overflow and cause
water damage.
IMPORTANT:
For hygienic reasons, the outlet hose must not be connected directly to the (4) waste
water system (see Fig. 5.2.b).
Insert the power plug
(1)
into the socket.