4.3 Technical data and operating conditions W19 L,LE,W
Model
W19 L
W19 LE
W19 W
General data
Machine dimensions
-excl.feet-
H x B x T (mm)
545 x 410 x 545
595 x 500 x 545
545 x 410 x 545
Adjustable feet
(mm)
10-25
Weight (kg)
41
Cooling
Air cooled
Water cooled
Refrigerant
R 290(GWP-value: 3)
Production data
Production (kg per day)
approx. 22
Storage (kg)
approx. 7
Water consumption of ice making
(Liter per kg ice)
approx. 3,3
Water consumption cooling system
(Liter per kg ice)
-
-
approx. 6,6
Power supply
Voltrage
230 V ~ / 50 Hz
Power consumption
0,18 kW
Fuse(provided by customer)
10 A
Length of connection cable
approx. 2,0 m
Water supply
Pressure
2 - 6 bar
Temperature
5°C-25°C
Water hardness
max. 25 °dH *)
max. 15 °dH *)
Water inlet
Device connection-Ø
¾“ –male thread
hose -Ø / -length
DN 8 (inkl. 2x ¾” –female thread) / about. 1,5 m
Water outlet
Device connection -Ø
20 mm
hose -Ø / -length
DN 20 / about. 1,4 m
Cooling water outlet
Device connection -Ø
-
-
10 mm
hose -Ø / -length
-
-
DN 10 / about. 1,4 m
Environmental conditions
Temperature
10-40°C
Installation position
Firm surface, good ventilation
Installation height
At least 10 cm above outlet pipe
The installation surface must be suitable for the weight of the machine
*if the water hardness exceeds the maximum value, the use of a softener is recommended.