35
2.11 Hydraulic
Maintenance
Monthly checks:
1. Oil Reservoir - Fluid level should be at the
venting plug with the hoist in the up position.
Oil, Chevron automatic transmission fluid,
“Dexron II” or equivalent.
2. Packing gland - Little water should weep
from the packing. It should not drip. If there is
too much water coming from the packing gland
tighten each of the cap bolts one full turn. Run
the hoist up and down and check for water. If
the packing gland cap has bottomed out, add one
new layer of packing, Wesmar part #09.00749.0
3. Check all wiring and hydraulic lines that may
catch or snag when the hoist is moving
Summary of Contents for SS395