Control Panel - User Manual
5 - Basic functions of the control panel
Doc.no.: UM-22031
Revision: D
Page 19 of 30
Picture 4 – Traversing Z-axis
Traversing C-axis: Turn joystick.
o
If you turn the joystick clockwise, the axis (turntable) also turns
clockwise.
o
If you turn the joystick anti-clockwise, the C-axis (turntable) is also
moved anti-clockwise
5.4. Aligning control panel with respect to measuring machine
It is easier to traverse the axes of the measuring machine and thus the measuring
probe, if the joystick and measuring probe move in parallel. For example: If you
move the joystick to the left, the measuring probe also trav-els to the left.
To make this also possible at different operating positions, the alignment of the
control panel with respect to the measuring machine can be changed.