50
Integrated Web Server
Signal Selection
All of the internal camera’s columns are searched for peaks. If two or more peaks are
detected in a single column, the user can specify the order in which the peaks are read
out as distance value Z.
NOTE!
This setting can be used to reduce reflection and other laser line interference.
The following selection criteria are available:
• Strength:
The strongest peak of the camera's column is output in the profile.
• Width:
The widest peak of the camera's column is output in the profile. A wider peak
occurs when the laser light penetrates more deeply into the object’s surface. The
peak width is not shown in in the profile display.
• First:
The first peak of the camera's column is output in the profile.
• Last:
The last peak of the camera's column is output in the profile.
Trigger Settings
Profile Mode
• Dynamic: The profile is recorded for as long as the trigger signal is applied.
Figure 1: “Dynamic” Profile Mode
Number of profiles
Trigger signal
Profile Mode
• Fixed After the “Number of Profiles” has been selected, precisely this number of pro-
files is recorded after the start event occurs (trigger, software command), and profile
recording is stopped automatically until the next start event occurs (see also “profile
enable” pin function).
Figure 2: “Fixed” Profile Mode
Number of profiles
Trigger signal
Number of
Profiles
Specifies how many profiles will be recorded before the sensor stops and can only be
restarted by a command or an input signal.
Can be combined with the “Internal”,
“syncIN” and “Encoder” modes
.
Summary of Contents for weCat3D MLSL
Page 20: ...20 Technical Data weCat3D MLWL1x3 0 PP PP weCat3D MLWL1x4 0 PP PP weCat3D MLWL1x5 PP PP 0...
Page 22: ...22 Technical Data weCat3D MLWL2x4 0 PP PP weCat3D MLWL2x5 0 PP PP...
Page 24: ...24 Technical Data weCat3D MLWLxxx weCat3D MLWL1x1 weCat3D MLWL1x2...
Page 71: ...71 2D 3D Profile Sensors...