6.5 Default Settings
WeCat3D MLSL
WeCat3D MLWL
Pin function
E/A1
Encoder E1+E2
Encoder E1+E2
E/A2
Encoder E1+E2
Encoder E1+E2
E/A3
Sync Out
Sync Out
E/A4
Sync In
Sync In
I/O settings
E/A1
Operating voltage active
Operating voltage active
E/A2
Operating voltage active
Operating voltage active
E/A3
Push-Pull
Push-Pull
E/A4
Operating voltage active
Operating voltage active
Encoder
Direction of rotation
Independent of direction
Independent of direction
Encoder scaling
0
0
Display
Intensity
Screensaver
Screensaver
Mode
Analysis
Analysis
Operating mode
Profile Sensor
Profile Sensor
Profile
Measuring rate (Hz)
200
175
Signal selection
Strength
Strength
Exposure time (µs)*
150
150
Measuring field (pix) Offset X
0
0
Width X
1280
2048
Offset Z
0
0
Height Z 1024
2048
Interface
IP address
192.168.100.1
192.168.100.1
Subnet mask
255.255.255.0
255.255.255.0
TCP port
32001
32001
Std. gateway
192.168.100.254
192.168.100.254
MAC address
See OLED display,
interface section
See OLED display,
interface section
Language
English
English
Password OLED
Deactivate/
activate
Deactivated
Deactivated
Change
„0000“
„0000“
Website
password
admin
admin
* A standard exposure time is set upon shipment from the factory. With some surfaces, exposure time has to
be matched to ambient conditions, i.e. increased or reduced.
6.6 Programming Interfaces
The exact commands can be taken from the documentation for the weCat3D-SDK (interface descriptions in
the product’s download area).
Summary of Contents for weCat3D MLSL
Page 20: ...20 Technical Data weCat3D MLWL1x3 0 PP PP weCat3D MLWL1x4 0 PP PP weCat3D MLWL1x5 PP PP 0...
Page 22: ...22 Technical Data weCat3D MLWL2x4 0 PP PP weCat3D MLWL2x5 0 PP PP...
Page 24: ...24 Technical Data weCat3D MLWLxxx weCat3D MLWL1x1 weCat3D MLWL1x2...
Page 71: ...71 2D 3D Profile Sensors...