Page 2: ...8 4 4 Complementary Products 9 5 Mounting Instructions 9 6 Initial Operation 10 6 1 Operation on a controller 10 6 2 Default Settings 10 7 Functional Overview OLED Display 11 7 1 Run 13 7 2 Display 1...

Page 3: ...nfiguration 22 9 1 Page layout 25 9 2 Device general 26 9 3 Device Settings 27 9 4 Measured Value Settings 28 9 5 Device Test 29 10 Maintenance Instructions 29 11 Proper Disposal 29 12 EU Declaration...

Page 4: ...bly detected Ethernet technology is integrated into selected sensors 2 Safety Precautions 2 1 Safety Precautions This operating instruction is part of the product and must be kept during its entire se...

Page 5: ...0000 Lux Beam Divergence 2 mrad Light Spot Diameter 3 6 0 9 mm Port Type 100BASE TX PoE Class 1 Temperature Range 25 50 C Reverse polarity Protection Yes Interface EtherCAT Protection Class III Adjust...

Page 6: ...240 300 360 420 480 540 600 660 1000 100 0 Working Range mm Linearity Deviation m OCP662P0150C Typical Linearity Error Curves within the Working Range 30 35 40 45 50 55 60 65 70 75 80 100 50 0 Working...

Page 7: ...B TTL Black Brown Red Orange Yellow Green Blue Violet Grey White Pink Green Yellow Supply Voltage Supply Voltage 0 V Supply Voltage AC Voltage Switching Output NO Switching Output NC Contamination Err...

Page 8: ...l Green on ESM state Operational Red off No Error Red on Application controller failure Flashing red once Local Error Flashing red twice Process Data Watchdog Timeout EtherCAT Watchdog Timeout Red fla...

Page 9: ...No 50 S81 Midspan Adapter Z0029 Switch with PoE ZAC50xN0x 4 Mounting Instructions When using the Sensor follow the corresponding electrical and mechanical regulations standards and safety rules The Se...

Page 10: ...IO EtherCAT in the installation folder The following example shows the steps that have to be carried out example based on the TwinCat System Manager by Beckhoff First the list Echtzeit Ethernet kompat...

Page 11: ...Max Power save Screensaver Process Text Analyse Network Mode Rotate Intensity Display Filter Resolution 1 10 100 2 20 5 50 SCM LCM DCM CCM Laser Illumination On Off E A Test Run Mode Value in m No of...

Page 12: ...ration menu by pressing any button Note If no setting is made in the configuration menu for a period of 30 s the Sensor returns automatically to the display view Pressing the button again returns the...

Page 13: ...the button the display is rotated by 180 The rotation is canceled by pressing this button again Intensity Set the display intensity see chapter 6 2 2 6 2 1 Display Mode The measured value in mm and t...

Page 14: ...an object and the slower the output rate of the Sensor becomes when there is a change in the measured values Resolution Adjust the display device High Medium Low 3 Back 7 Run High High resolution low...

Page 15: ...g black varnish in order to achieve a more accurate measurement DCM Default Capture Mode Default exposure time for standard applications CCM Custom Capture Mode The Sensor exposure time can be adjuste...

Page 16: ...f the following bits is set 2 Distance to object too small The current measured value is below the working range Measuring range lower limit 3 Distance to object too large The current measured value i...

Page 17: ...d language at initial operation and after each reset Language Set menu language Deutsch English Francais Espanol Italiano 3 Back 7 Run The menu appears in the selected language immediately after selec...

Page 18: ...iate disabling of operation if activate Password is set to on If the password functionality is activated the password must be entered before each operation of the Sensor After correctly entering the p...

Page 19: ...fault parameters 00h Highest subindex supported Unsigned 8 Ro No 1 1 01h Restore all parameters Unsigned 32 Rw No 0 64616F6Ch restore any other don t rest 1018h Identity Object 00h Highest subindex su...

Page 20: ...ss BOOL Rw No 0 Enabled 0 1 0 Enabled 1 Disabled 02h Key disabling BOOL Rw No 0 Enabled 0 1 0 Enabled 1 Disabled 2100h Display settings 00h Highest subindex supported Unsigned 8 Ro No 5 0 254 5 01h Di...

Page 21: ...al 2 DCM mode 0 3 0 SCM mode 1 LCM mode 2 DCM mode 3 CCM mode 06h Exposure time Unsigned 16 Rw Optional 1000 s 100 8000 Max exposure time 100 8000 s 2130h 00h Measured value Unsigned 32 Ro Yes Distanc...

Page 22: ...instructions Start Up EtherCAT Device www wenglor com Download Operating Instructions Product Search Order Number General instructions in the chapter Displaying and working with the integrated web se...

Page 23: ...23...

Page 24: ...TwinCAT in the area EoE of the Device The overview page Device General is not password protected If the pages of the device or port settings are accessed a password prompt appears The following user d...

Page 25: ...on the device itself 3 Category selection The web based settings are divided into four categories Device general Overview page with general information about the device Device settings Network and di...

Page 26: ...26 EN 8 2 Device general After establishing the connection the overview page Device general is displayed...

Page 27: ...tional description of display settings see chapter 6 2 Display on page 13 Change password An additional window opens in which the new password can be entered Note If the password is forgotten it s onl...

Page 28: ...e chapter 6 4 Filter on page 14 Exposure For functional description of exposure see chapter 6 5 Exposure on page 15 Emitted Light For functional description of transmitted light see chapter 6 7 Laser...

Page 29: ...ff Note Settings are retained in the online state as well 9 Maintenance Instructions This wenglor Sensor is maintenance free It is recommended to clean the lens and the display regularly and to check...