5. Initial Operation
5.1. Operation on a controller
If you want to place the device into service at a controller, please complete the following steps:
• Connect the Sensor to a switch with PoE using an appropriate cable M12×1; 8-pole. In the case of a switch
without PoE, please use the Midspan Adapter (Z0029) for the appropriate voltage supply. When the voltage
supply is present, the display on the Sensor starts.
• You will need the EtherCAT XML Device Description File (ESI-File EtherCAT Slave Information) which is avail-
able at www.wenglor.com › Product › Product search (Order number) › Product Description Files or in the
download area under Download › Product Description Files › Product search › Order number.
• The files should always be stored in the ESI directory of the respective master. If the Twin-CAT software is
used, it should be stored in the folder “...\IO\EtherCAT\” in the installation folder.
• The following example shows the steps that have to be carried out (example based on the TwinCat System
Manager by Beckhoff):
• First, the list “Echtzeit Ethernet kompatible Geräte” (list of all real-time Ethernet-compatible devices) must be
requested.
• Once the correct network card has been installed, new slave devices can be searched for in “E/A Geräte” (I/O
devices). If all configurations are correct, the slave devices are now listed in the TwinCAT tree.
• The assemblies can now be switched into “Free Run” mode so that the local cycle runs independently of the
pre-set master cycle.
• In the next step, the process data of the individual devices can be configured.
For a more detailed description of the different control systems and the installation of files or the network de-
sign, please refer to the help files of the corresponding control system.
5.2. Default Settings
OCPxxxP0150P
Display
Mode
Process
Intensity
Screensaver
Filter
1
Resolution
High
Exposure
DCM
Output Rate
Normal
Laser
ON
Password
Activate
Off
Change
0