background image

CMP201D User Guide

45

For the Output, both models have direct IP output and multiplexing, but only CE2-HDMI-R01 has
RTMP output settings.

This feature is specifically for single program encoding and IP output directly. Outputting in this way
will not occupied baseboard multicast bandwidth.

If you want to use IP output channel in the encoder module and the baseboard IP module at the

same time, you should avoid a multicast IP address conflict. If there are two same IP addresses
enabled meantime, all the multicast videos will be affected.

Destination IP Address

and

Destination Port:

Using for multicast IP addresses or unicast IP

addresses and ports.

Enable Destination MAC:

Generally, you do not need to enable this option. This is reserved for

exceptional cases where the unicast stream cannot be received with unicast IP addresses. You
can enable destination MAC and streaming out by setting Destination MAC.

Advance Setting (only available in CE2-HDMI-00):

The second eth is reserved for you to output IP streams in an another different VLAN. You can
output unicast streams to the another VLAN by enabling the second eth and setting

IP Address

,

Subnet Mask

,

Default Gateway

in the same segment of the unicast IP (the another different VLAN).

Summary of Contents for CMP201

Page 1: ...CMP201D Media Platform User Guide V1 5 W...

Page 2: ...nored may cause physical harm to the user CAUTION The CAUTION symbol calls your attention to a situation that if ignored may cause damage to Our product NOTE The NOTE symbol calls your attention to im...

Page 3: ...current circuits Do not work on the system during periods of lightning Refer all servicing to qualified service personnel Servicing is required when this unit has been damaged in any way Damage Requir...

Page 4: ...ng 13 4 4IP Input 16 4 5 IP output 20 4 6 Admin 23 5 Module Configuration 5 1 Receiver Modules 5 Module Configuration 24 5 1 Receiver Modules 24 5 1 1CR2 DVBC 00 24 5 1 2 CR2 DVBS2CI 00 28 5 1 3 CR2 D...

Page 5: ...ISDBT R01 R01A 92 5 3 6 CM2 MOD 02 94 5 4 Function modules 112 5 4 1 CP2 EAS 00 112 5 4 2 CP2 CAM 00 115 5 4 3 CP2 EIT 00 121 6 Appendices 126 Appendix A Abbreviations 126 Appendix B Warranty 128 Appe...

Page 6: ...video delivery requirements of signal receiving descrambling encoding multiplexing modulation and IP processing depending on a variety of models Due to its compact design powerful functions super prac...

Page 7: ...CMP201D User Guide 4 1 2 Back Panel CMP201D I 6 hot swappable modules II Dual Power Supply III Ground...

Page 8: ...tion if there s no supporting plate in the rack 3 Insert the rack mount clips into place over the mounting holes in the rack 4 Slide the CMP201D into the position in the rack 5 Secure the chassis to t...

Page 9: ...ondition the equipment should be acclimated to the warm and humidity condition for at least 30 minutes Powering up a non acclimated unit may lead to shortcut or other damage to ele ctronic components...

Page 10: ...ith 4 8 RF connectors CR2 DVBS2FTA 01 4 channel DVB S S2 S2XFTA receiving module with 4 RF connectors CR2 8VSB 00 4 channel 8VSB receiving module with 4 RF connectors CR2 DVBT2CI 00 4 channel DVB T T2...

Page 11: ...commercial chip 16 channel CVBS encoding module supports H 264 SD MPEG1L2 AAC optional AC3 optional commercial chip CE2 SDI 00 2 channel SDI HD encoder supports H 264 MPEG 2 HD SD MPEG1L2 AAC optiona...

Page 12: ...djacent frequencies modulating with 1 RF female connector for output supports up to 4 8 adjacent frequencies modulating with 1 RF female connector for output CM2 OFDM R01 R01A supports up to 4 8 adjac...

Page 13: ...card descrambling and the number of descrambled services is defined by the CAM card It supports descrambling services which are multiplexed from different IP RF channels or modules CP2 EIT 00 EIT mul...

Page 14: ...cess the Web GUI in a browser Connect laptop computer to CMP201D management port directly Set the IP address of the laptop computer in the same network segment with the CMP201D Baseboard CMP201D will...

Page 15: ...ween CMP201D and PC or other devices this switch should support IGMP V2 and IGMP snooping function If the switch you used is not configured properly it could cause some network issue 4 1 2 Logging int...

Page 16: ...t Edge you may encounter incomplete UI layouts and configure setting in these browsers may lead to errors Status Device Information Device Information page shows the firmware version software version...

Page 17: ...rd IP address The occupied IP section will be displayed in this page on the top blue area System Setting Time In Time page you can see the current system time change Time Zone choose system time Mode...

Page 18: ...an upgrade import or export configuration import or export license only for baseboard reboot the whole unit restore it to factory setting only for baseboard export log and clear log only for baseboard...

Page 19: ...sic Setting and Service Configuration IP Input Status In this page you can check each channel Total Bit Rate Effect Bit Rate TS Analysis and Service List Click the icon in the TS Analysis list to see...

Page 20: ...e bandwidth table type service name in the search bar to get the info you want Service List Click a service name to check the detailed info of this service IP Input Settings Here you can configure IP...

Page 21: ...want to configure a batch of channels please click Batch Setting To set the IP input parameters in batch you can check the boxes before parameters you need then choose modify the values Click Apply to...

Page 22: ...the output channel of this stream After you select bypass mode this output channel will be occupied only by this stream and when you set other stream output channels this channel will not be available...

Page 23: ...tton on top Normally the input service list of each channel will load itself on this page but when you change the input source the list could not refresh immediately You can refresh the changed channe...

Page 24: ...imilar to Setting IP input Multicast output setting You should fill the fit multicast IP addresses as output in the Destination IP Address box Please avoid IP conflict among baseboard encoder modules...

Page 25: ...IP addresses Constant Rate of any output channel TS port ought to be set manually about 2 Mbps higher than the Effective Bitrates in the corresponding output channel TS port since the Effective Bitrat...

Page 26: ...k TS line the blue area to configure Original Network ID TS ID and each Service ID Service Name and Service Provider NIT setting Please refer to CM QAM 00 module 4 6 Admin Click Admin and you can choo...

Page 27: ...receive 4 RF channels signal simultaneously and support 2 CAM cards descrambling Click CR2 DVBC 00 in the Module List then go to CR2 DVBC 00 module page CR2 DVBC 00 Status Click TS Analysis of each c...

Page 28: ...CMP201D User Guide 25 Click the icon to check service information of all the inputs You can check program details by clicking the program item...

Page 29: ...e CAM module and Smart Card You can select the CAM Max Bit Rate from 48Mbps to 108Mbps in pull down list depending on the total effective bitrate of services you want to decrypt at Click the Apply but...

Page 30: ...the input channel toward the available output channels IP or RF Two types of routing are possible 1 Bypass mode In this mode you can route a whole input transport stream towards an IP or RF output whi...

Page 31: ...s you can also perform Import Export License Reboot the module Restore the unit to factory defaults and Log Export Clear 5 1 2 CR2 DVBS2CI 00 CR2 DVBS2CI 00 is a 4 channel DVB S S2 receiving and descr...

Page 32: ...ach other via LNB 1 Channel 2 1 and 2 2 share power via LNB 2 Name Range Satellite Frequency KHz 950000 21500000 Symbol Rate KBaud 1000 45000 LNB Frequency KHz 950000 21500000 LNB Power Off 13v 18v LN...

Page 33: ...VBS S2 receiving module with 8 RF connectors occupying 2 slots on the CMP201D chassis 5 1 4 CR2 DVBS2FTA 01 CR2 DVBS2FTA 01 is a 4 channel DVB S S2 S2XFTA receiving module with 4 RF connectors and 4 L...

Page 34: ...ch as PIDs Type or service for a quickly search Click the icon to check service information of all the inputs You can check program details by clicking the program item CR2 DVS2FTA 01 Parameter Settin...

Page 35: ...on on the right side to make the changes made take effect CR2 DVS2FTA 01 Biss Here you can create Biss ID including Mode Key and Injected ID And you can check the Service Information in the Service Li...

Page 36: ...ll configuration Scanning Time ms 1000 5000 Please try to increase this value if service name is not present while it will slow down scanning process CR2 DVS2FTA 01 IP Output This feature enables you...

Page 37: ...st IP ports and parameters of IP Output There is also Batch Setting The destination IP address can be multicast IP address or unicast IP address There are 64 IP output channels Mark the Enable checkbo...

Page 38: ...dresses conflicts If there are two identical IP addresses enabled concurrently both the multicast transport streams will be affected IP Output Service Configuration Users can make configuration for ou...

Page 39: ...ID and each Service ID Service Name and Service Provider etc NIT setting Click the icon to modiify NIT Network and NIT Stream CR2 DVS2FTA 01 System Operation On System Operation page you can import ex...

Page 40: ...o analyze and fix them Turn on Enable Real time Log switch see the real time log messages and the security level of each message below Click to clear all log messages on the screen Click to delete all...

Page 41: ...ors 8VSB receiver is mainly adopted on ATSC standard CR2 8VSB 00 Status CR2 8VSB R01 R01A Basic Setting 4 channels receiving is supported with 4 connectors All the CHs at specific frequency points are...

Page 42: ...MHz CH4 69MHz CH133 849MHz CH134 855MHz CH135 861MHz HRC CH2 55 75MHz CH3 61 75MHz CH4 67 75MHz CH133 847 75MHz CH134 853 75MHz CH135 859 75MHz Status Service Configuration and System is similar to CR...

Page 43: ...the right side to make the change take effect Status CI Service Configuration and System please refer to CR2 DVBC 00 5 2 Encoder Modules 5 2 1 CE2 HDMI 00 R01 CE2 HDMI 00 is a 4 channel HDMI input enc...

Page 44: ...R01 Status CE2 HDMI 00 R01 Basic Setting Click Advanced Setting to see all parameters you can modify and check what specific parameters you want to set and see Click the Apply button on the right sid...

Page 45: ...20000 Service Name Length is 1 16 Video Min Bitrate K bps 0 Service Provider Na me Length is 1 16 Video Resolution Auto 1920 1080_60i 1920 1080_50i 1920 1080_30p 1920 1080_25p 1080 720_60p 1080 720_5...

Page 46: ...Bitrate KHz 48 Audio Mode Dual Channel Mono Stereo Audio PID 32 8190 Encoding Bitrate Kbps 128 384 AC3 64 384 MPEG1_Layer2 32 384 MPEG2_AAC MPEG4_AAC Volume 0 8 CE2 HDMI R01 Basic Setting CE2 HDMI R01...

Page 47: ...GH MAIN Provider Name Length is 1 16 Video PID 32 8190 Audio Encode Settings Range Audio Encode Settings Range Audio Type MPEG1_Layer2 AC3 AAC Audio PID 32 8190 Audio Bit rate Kbps 32 192 Volume dB 20...

Page 48: ...eos will be affected Destination IP Address and Destination Port Using for multicast IP addresses or unicast IP addresses and ports Enable Destination MAC Generally you do not need to enable this opti...

Page 49: ...eck Multiplex for the Channel you want to output through You can output multiple services in the same channel or output the same service in multiple channels To use RTMP output to configure streaming...

Page 50: ...pictures at the same time and pick one to show on the screen The feild of the selected picture will turn green LOGO Parameter Range LOGO Parameter Range Position X 0 1920 Dual Position Y 0 1080 Dual S...

Page 51: ...Range Position Bottom Top Middle Position Offset 200 200 Horizontal Pixel 10 1920 Scrolling Speed 1 20 Front Color White Black Blue Green Red Yellow Front Size 0 100 Display Interval 0 100 QR Code se...

Page 52: ...Dual Size width 0 1920 Dual Size Height 0 1080 Dual CE2 HDMI 00 R01 System Please refer to CR2 DVBC module 5 2 2 CE2 HDMI 02 CE2 HDMI 02 is a 2 channel HDMI encoder which supports H 264 HD SD or MPEG...

Page 53: ...ng Click Basic Parameters then click Advanced Setting to see Video Parameters Audio Parameters Service Parameters that you can modify and check what specific parameters you want to see and set Click t...

Page 54: ...0 Service Name Length is 1 16 Video Min Bitrate Kbps 2000 Service Provider Name Length is 1 16 CC Enable Diaable Video PID 32 8190 Video PID 32 8190 Video Aspect Ratio Auto 16x9 4x3 GOP Structure IBBP...

Page 55: ...dual audio encoding per channel which means one audio track from HDMI input can be encoded into two different formats for output CE2 HDMI 02 Output This feature is specifically for single program enc...

Page 56: ...to one channel or output one service to multiple channels CE2 HDMI 02 EAS Settings This function need to be used together with CP2 EAS 00 module The parameters of EAS Source Multicast Address Command...

Page 57: ...audio CC subtitle and analog audio input CE2 HDMI 02C Status CE2 HDMI 02C Basic Setting Click Basic Parameters then click All Configurable Parameters to see Video Parameters Audio Parameters Service...

Page 58: ...is 1 16 Video Min Bitrate Kbps 2000 Service Provider Name Length is 1 16 CC Enable Diaable Video PID 32 8190 Video PID 32 8190 Video Aspect Ratio Auto 16x9 4x3 GOP Structure IBBP IPPP IBP P Frame IBB...

Page 59: ...port and 1 DB 15port 2 channel share same one DB 15 port If video comes from HDMI there are three options for encoding dual audio 1 One audio comes from HDMI input and the another comes from analog in...

Page 60: ...received with unicast IP addresses you can enable destination MAC and streaming out by setting Destination MAC To use Multiplexing mode at service level 1 Click on the pencil icon There will always b...

Page 61: ...ick the check box to select the program s needing to be paved Click the Apply button on the right side to make the change take effect CE2 HDMI 02C System Please refer to CR2 DVBC DTMB module 5 2 4 CE2...

Page 62: ...Effective Bitrate TS anaylsis and Program Name The following parameters will display values once a good SDI source is connected CE2 SDI 00 Basic Setting Click Basic Parameters then click Advanced Sett...

Page 63: ...dio AAC Format 128 384 AC3 64 384 MPEG1_Lay er2 MPEG2_AAC AC3_Passthrough 16 384 MPEG4_AA C ADTS LATM Volume 20 20 Audio PID 32 8190 Input Source Type CVBS SDI GOP Size 18 48 Video Type H264 MPEG2 PCR...

Page 64: ...d to enable this option This is reserved for exceptional case when the unicast stream cannot be received by using unicast IP addresses you can enable destination MAC and streaming out by setting Desti...

Page 65: ...witched to the AV or ASI service from EAS module Service There are 2 programs corresponding to 2 HDMI Component ports Status Paved Unpaved EAS Override Tick the check box to select the program s needi...

Page 66: ...is similar to CE2 HDMI module Please refer to that module section CE2 CVBS 00 Settings Click Advanced Setting to see all parameters you can modify and check what specific parameters you want to set a...

Page 67: ...ness 0 255 Video Max Bitrate Kbps 0 Contrast 0 255 Video Min Bitrate Kbps 20000 Saturation 0 255 Video PID 32 8190 Hue 180 180 GOP Structure IPPB IPPP IBP VLC Mode CABAC CAVLC GOP Size 6 63 Profile HI...

Page 68: ...nd CE2 CVBS R01A module has 16 channels with 4 DB15 connectors The configuration of them are similar to CE2 CVBS 00 there are a few differences on parameter setting range Name Range Name Range Video T...

Page 69: ...e dB 20 20 Delay ms 2000 2000 CE2 CVBS 00 R01 R01A Output Insertion Output and Insertion please refer to CE2 HDMI R01 module CE2 CVBS 00 R01 R01A System Please refer to CR2 DVBC module 5 2 6 CE2 HDMI...

Page 70: ...ing This page allows you to modify the Video Audio and Service Parameters Click Advanced Setting to see all parameters you can modify and check what specific parameters you want to set and see Click t...

Page 71: ...3 SD Provider Name Length is 0 31 Profile MAIN HIGH Click Service Info in the line of Audio Encoding to set audio encoding Audio Encoder Details Range Audio Encoder Details Range Audio Enable Enable...

Page 72: ...eantime all the multicast videos will be affected Destination IP Address and Destination Port Using for multicast IP addresses or unicast IP addresses and ports Enable Destination MAC Generally you do...

Page 73: ...1D User Guide 70 LOGO setting you can upload several pictures at the same time and pick one to show on the screen The field of the selected picture will turn green LOGO Parameter Range LOGO Parameter...

Page 74: ...2 1080 Dual OSD setting Subtitle Parameter Range LOGO Parameter Range Position Bottom Top Middle Position Offset 200 200 Horizontal Pixel 10 1920 Scrolling Speed 1 20 Front Color White Black Blue Gre...

Page 75: ...e Parameter Range QR Code Parameter Range Position X 0 1920 Dual Position Y 0 1080 Dual Size width 0 1920 Dual Size Height 0 1080 Dual CE2 HDMI 05A Output Output configuration please refer to CR2 DVBC...

Page 76: ...Logs 5 2 7 CE2 HDMI 06 CE2 HDMI 06 is a 4 channel HDMI encoder broadcast level It supports H 264 H 265 HD SD encoding up to 1080p60 B frame de interlacing Audio encoding of MPEG1 L2 AAC optional and A...

Page 77: ...H 265 Video PID 32 8190 Video Bitrate Kbps 600 12000 PCR2 PID 32 8190 GOP Size 1 60 PMT PID 32 8190 Video Resolution Auto Manual Horizontal Pixels 160 1920 Vertical Pixels 120 1080 Framerate 24 60 Sc...

Page 78: ...you want to use IP output channels in the encoder module and baseboard IP Output module at same time you should avoid a multicast IP address conflict If there are two same IP addresses enabled meantim...

Page 79: ...o output the service to Check Multiplex on the channel you want to output to You can output multiple services to one channel or output one service to multiple channels CE2 HDMI 06 Insertion You should...

Page 80: ...CMP201D User Guide 77 LOGO Parameter Range LOGO Parameter Range Position X 0 1920 Dual Position Y 0 1080 Dual Size width 2 1920 Dual Size Height 2 1080 Dual OSD setting...

Page 81: ...btitle Parameter Range LOGO Parameter Range Horizontal Pixel 10 1920 Scrolling Speed 1 20 Front Color White Black Blue Green Red Yellow Front Size 0 100 QR Code setting QR Code picture picking method...

Page 82: ...CMP201D User Guide 79 QR Code Parameter Range QR Code Parameter Range Position X 0 1920 Dual Position Y 0 1080 Dual Size width 0 1920 Dual Size Height 0 1080 Dual CE2 HDMI 06 System...

Page 83: ...for modulating output and 1 RJ45 network port is reserved for future use QAMA and B share the same Hardware but Different Software If you need to change the Module from A to B please contact your loc...

Page 84: ...er and IP input will be seen here TS setting Please refer to IP output service configuration LCN setting You need to add NIT streams of all frequencies in the base TS frequency which is used for your...

Page 85: ...set on Modulator module only Do same operations to add next TS frequency until NIT streams of all the frequencies have been included At last click Apply button to let all configuration take effect The...

Page 86: ...rval ms 50 10000 RF level 25 45dBmV 85 105dB V Frequency KHz 48000 862000 QAM Mode QAM16 32 64 128 256 CM2 QAMA R01 R01A Output QAM Output will be different from the Receiver and Encoder module Since...

Page 87: ...IDs Fill the Original Network ID and TS ID of each TS frequency in the field of the base TS frequency and then click Add to create a NIT stream for this TS frequency Click Descriptor then LCN Descrip...

Page 88: ...ur STB you will get all programs in the order of LCN you set 5 3 2 CM2 8VSB R01 R01A CM2 8VSB R01 R01A module supports up to 4 8 8VSB adjacent frequencies modulating with 1 RF connector for output Mod...

Page 89: ...r to IP output service configuration To use this board you need to change the Standard to ATSC in Advance Settings System Settings Don t forget to click APPLY when you finish configuration 5 3 3 CM2 Q...

Page 90: ...make the change take effect Name Range Name Range Bandwidth MHz 6 Channel Standard STD IRC HRC Symbol Rate KBaud 5056 941 QAM 64 5361 QAM 256 RF level 75 105 dB V 15 45 dBmV PSI SI Interval ms 50 1000...

Page 91: ...Module configuration is similar to IP Setting CM2 QAMB R01 R01A Basic Setting Click the Apply button on the right side to make the change take effect Name Range Name Range Symbol Rate KBaud 5057 QAM6...

Page 92: ...TS should have different IDs Fill the Original Network ID and TS ID of each TS frequency in the field of the base TS frequency and then click Add to create a NIT stream for this TS frequency Click De...

Page 93: ...l get all programs in the order of LCN which you set 5 3 4 CM2 OFDM R01 R01A CM2 OFDM R01 R01A module supports up to 4 8 adjacent frequencies modulating with 1 RF female connector for output Module co...

Page 94: ...TS should have different IDs Fill the Original Network ID and TS ID of each TS frequency in the field of the base TS frequency and then click Add to create a NIT stream for this TS frequency Click De...

Page 95: ...n your STB you will get all programs in the order of LCN which you set 5 3 5CM2 ISDBT R01 R01A CM2 ISDBT R01 R01A module supports up to 4 8 adjacent frequencies modulating with 1 RF female connector f...

Page 96: ...ginal Network ID and TS ID of each TS frequency in the field of the base TS frequency and then click Add to create a NIT stream for this TS frequency Click Descriptor and Cable Descriptor Fill in the...

Page 97: ...ing programs in your STB you will get all programs in the order of LCN you set 5 3 6 CM2 MOD 02 CM2 MOD 02 is a 32 channel QAM A modulation output module with 2 gigabit IP input ports single port supp...

Page 98: ...vided into two RJ45 ports each port has 512 IP input channels Click Port 1 tab users can obtain the 256 channels status information such as input source IP address and port number total bitrate Mbps a...

Page 99: ...the PIDs such as PAT CAT PCR2 Video Audio PCR2 PID etc in this TS See the image below for reference If the input stream has multiple programs users can click the icon below Service List to see all th...

Page 100: ...atus shows the Modulation output Just like the IP Input this shows the total bitrate and effective bitrate of the 32 channels respectively The TS Analysis and Service List have the same function as in...

Page 101: ...status also shows the IP output Just like the IP Input this shows the total bitrate and effective bitrate of the 16 channels respectively The TS Analysis and Service List have the same function as in...

Page 102: ...P port and parameter of IP Input There are Port 1 Port 2 and Batch Setting The input can accept Multicast or Unicast and support MPTS and SPTS Port 1 and Port 2 have same interface It shows the 512 ch...

Page 103: ...input the IP input parameters in batch See the image below for reference Modulation Output Parameter Setting On this page you can enable channels as you need and input the Frequency KHz QAM Mode Symb...

Page 104: ...ncy KHz 47000 999000 QAM Mode QAM16 QAM32 QAM64 QAM128 QAM256 Symbol Rate KBaud 3600 and 6952 RF Level Gain dBmV 10 0 The value must be a number multiple of 0 5 RF Level dBmV 90 120 PSI SI Interval ms...

Page 105: ...nd parameter of IP Output There are Port 1 Port 2 and Batch Setting The output can accept Multicast or Unicast and support MPTS and SPTS Port 1 shows the 16 channels Check the box under Enable to enab...

Page 106: ...IP output parameters in batch See the image below for reference CM2 MOD 02 Multiplexing Multiplexing has four tabs Source Service Configuration SI Table Setting and PID Transmission Here you are can...

Page 107: ...r output You can chose Port 1 or Port 2 for the source Each port is divided into 16 groups to complete 512 channels Select a Port and you can see service lists of Group and Channel as shown below To o...

Page 108: ...transferring it to output Multiplexing Service Configuration After output the services from IP input to Modulation output you can now edit the Service ID and other PID on the output Click on the Servi...

Page 109: ...Original Network ID and TS ID of the Modulation Output Here you can also edit NIT and create NIT Network for the OTA upgrade Still in NIT you can also create NIT Streams and generate LCN for channel l...

Page 110: ...s For the Cable Descriptor input the correct frequency and SymbolRate for the corresponding TS output Cable descriptor depends on the setup you use Mostly Cable descriptor is created for 1 TS only Som...

Page 111: ...ambling CM2 MOD 02 Scramble is where you can encrypt a service on the Modulation Output Scrambler can be connected 6 different CAS simultaneously There are seven tabs on this page namely Service Scram...

Page 112: ...m for encryption as you need then select the CA ID of the service Click Apply to finish setting The Modulation Output Channel will only list the enabled channels but not all 32 channels If the channel...

Page 113: ...you can modify the IP Address Subnet Mask and Gateway for each port of the module except for the address of the module itself This also shows the MAC Address of each port of the module See the image...

Page 114: ...analyze and fix them Turn on Enable Real time Log switch to see the real time log messages and the severity level of each message below Click to clear all log messages on the screen Click to delete a...

Page 115: ...This feature is for the US market and requires the CMP201D chassis to be set for ATSC standard A common application of Emergency Alert Systems is for Broadcast and Audio Muting The trigger switched vi...

Page 116: ...CMP201D User Guide 113 CP2 EAS 00 Basic Setting...

Page 117: ...g2 AAC Mpeg4 AAC Video Bit rate Kbps 1500 20000 Audio Bit rate Kbps 128 192 256 384 Volume 10 10 When you set the IP output of the EAS module you should set the same parameters for other modules that...

Page 118: ...most all kinds of CAM card descrambling and the number of descrambled services is defined by the CAM card It supports descrambling services which are multiplexed from different IP RF channels or modul...

Page 119: ...ee the TS analyzing result of this channel Click the icon below the Service List to see the Services of this channel TS Analysis Click Reset Counter to clear continuity count error and restart countin...

Page 120: ...CI CI page not only shows the CAM card name and CA system ID but also shows the service PID service information and scrambling descrambling status CAM Max Bitrate is from 48Mbps to 108Mbps which you...

Page 121: ...module is licensed to scramble on this page you can set the output destination of all services When this module is licensed to descrambe on this page you can select the descrambled services and set th...

Page 122: ...de through pull down list Click Apply to save the change When this module is licensed to descramble it only can be served as descrambling On System Operation page you can Import Export License Reboot...

Page 123: ...CMP201D User Guide 120 Click to clear all log messages on the screen Click to delete all log information Click to export log information Click to filter desired log message...

Page 124: ...multiplexing modules can run simultaneously in a single chassis The GUI of EIT module includes three pages Status Module Setting and System CP2 EIT 00 Status The Status Page displays modules and servi...

Page 125: ...ble Click Apply button on the right side to make the changes made take effect When there is a CP2 EIT 00 module you should still start the configuration from receiving modules and output the required...

Page 126: ...disable the EIT multiplexing for specific services and check the EIT multiplexing status EIT function is enabled on modulation module and disabled on IP output of baseboard by default All service list...

Page 127: ...of the module If there are issues encountered on this module exporting the logs will help R D team to analyze and fix them Turn on Enable Real time Log switch to see the real time log messages and the...

Page 128: ...CMP201D User Guide 125 Clicking the filter icon you can simply select what logs to be included...

Page 129: ...n Systems Committee AV Audio Video BAT Bouquet Association Table BER Bit Error Ratio Bit Rate The rate at which the compressed bit stream is delivered BNC British Naval Connector CAM Conditional Acces...

Page 130: ...ransport Stream NIT Network Information Table OFDM Orthogonal Frequency Division Multiplexing PAT Program Association Table PCR Program Clock Reference PID Packet Identifier PMT Program Map Table PSI...

Page 131: ...component Before any product can be returned for service the client ought to contact our sales representatives and after sales support department by means of email to confirm the need to return the p...

Reviews: