34
IOM-189
MODEL: INFLOW™ ACE MANUAL INSERTION
REV: G
13839 West Bellfort Street, Sugar Land, TX 77498
welker.com
Service Department 281.491.2331
Disassembling the Upper Housing
20.
If the inFlow™ ACE is not equipped with the optional external adjustment, continue to step 21. If the inFlow™ ACE is
equipped with the optional external adjustment, proceed to step 23.
Without Optional External Adjustment Assembly
21.
Unscrew the bolts from the top cap and carefully remove the top cap from the motor housing (
22.
With Optional External Adjustment Assembly
Figure 20: External Adjustment Assembly
23.
Unscrew the motor top from the motor housing.
24.
Carefully remove the motor top from the external adjustment body.
25.
Carefully unscrew the external adjustment body from the insertion shaft. Note that the external adjustment rings will
remain attached to the external adjustment body and will also be removed at this time.
26.
Unscrew the cap screws from the top cap and carefully remove the top cap from the motor housing (
27.
Unscrew the setscrews from the base of the packing gland body (
28.
Unscrew the packing gland body from the outer shaft.
29.
Unscrew the packing gland body from the motor housing, and then carefully remove the packing gland body from the
insertion shaft. Take care not to scratch or otherwise damage the insertion shaft.
30.
Carefully pull the insertion shaft out through the motor housing.