30
IOM-189
MODEL: INFLOW™ ACE MANUAL INSERTION
REV: G
13839 West Bellfort Street, Sugar Land, TX 77498
welker.com
Service Department 281.491.2331
3.2 Maintenance: Optional Insertion Tool
1.
Prior to performing maintenance on the optional insertion tool, the inFlow™ ACE must be removed from the pipeline.
See
Section 2.8, Retracting the Unit,
for instructions on retracting the insertion shaft and removing the inFlow™ ACE from
the pipeline.
2.
Lay the inFlow™ ACE on a smooth, clean surface with the tube fittings facing up.
Removing the Insertion Tool
Figure 16: Insertion Tool Diagram
3.
Remove the hex nuts, flat washers, and lock washers from the top of each insertion tool shaft and upper bracket
standoff.
4.
Remove the top brackets.
5.
Unscrew the fastener screws from the upper bracket plate, and then loosen the front fastener screw on the upper
bracket.
6.
Holding the upper bracket standoffs, carefully lift the stabilizer bar and upper bracket from the motor housing.
7.
Remove the bracket bolts from the lower bracket.
8.
Unscrew the fastener screws from the lower bracket plate, and then loosen the front fastener screw on the lower
bracket.
9.
Holding both insertion tool housings, carefully lift the lower bracket from the lubricator body. Note that the lower
bracket will remain attached to the insertion tool housings.