36
IOM-189
MODEL: INFLOW™ ACE MANUAL INSERTION
REV: G
13839 West Bellfort Street, Sugar Land, TX 77498
welker.com
Service Department 281.491.2331
Packing Gland Body
Figure 23: Packing Gland Assembly
37.
Slide the gland cover off the packing gland body.
38.
Replace the O-ring on the packing gland body.
39.
Unscrew the packing adjustment nut from the packing gland body.
40.
Inspect the wiper ring in the packing adjustment nut. Replace it if it shows signs of wear or damage.
41.
Replace the V-ring packing in the packing gland body. The V-ring packing should be installed so that the "V" is open to
the product pressure.
42.
Remove the cartridge seal body assembly from the packing gland body.
43.
Install a replacement cartridge seal body assembly to the packing gland body.
44.
Screw the packing adjustment nut into the packing gland body but do not tighten.
45.
Replace the O-ring in the packing gland body.