3. INSTALLATION

This must be carried out by skilled personnel. All 

connections must be carried out according to current 

regulations, and in full observance of safety laws (CEI 

reglement 26-10 – CENELEC HD 427). 

-   Make sure that the supply voltage matches the 

voltage indicated on the specifications plate.

-  When mounting a plug, make sure it has an 

adequete capacity, and that the yellow/green 

conductor of the power supply cable is connected to 

the earth pin.

WARNING! Extension cords of up to 30 m must have a 

crosssection of at least 2.5 mm².

3.1 DESCRIPTION OF THE EQUIPMENT

1)  MIG Welding Torch Adapter (Euro connector).

2)  Earth cable output terminal 

(-)

3)  Shielding Gas Inlet.

4)  Power switch: control power through and break

5)  Power Access client: access to cable

6)  Fan: for cooling the machine.

7)  Digital display (Voltage).

8)  Digital display (Welding current, Wire speed).

9)  Indicates that the display 

(8)

 shows the MIG 

welding wire speed.

10) Indicates that the display 

(8)

 shows the welding 

current.

11) Power indicator: Indicates that the machine is 

turned on.

12) The indicator will illuminate if the duty cycle of the 

power source has been exceeded.

13) Switch for wire feed and Gas Test.

14) Wave control: Is used to adjust the intensity of the 

welding arc.

15) Setting knob: In relation to the selected LED, 

regulates: the welding current

 

(LED 10)

 or wire speed in MIG welding 

(LED 9)

.

16) Setting knob: regulates welding voltage.

3.2 REEL FITTING SEQUENCE

1.  Mount the wire reel.

2.  The wire reel hub incorporates a friction brake which 

is adjusted during manufacture for optimum breaking. 

If it is considered necessary, adjustment can be made 

by turning the large nut inside the open end of the 

hub clockwise to tighten the brake.

3.  Use the nut to secure the wire reel.

3.3 WIRE FEED

Make sure that the groove of the rollers matches the 

wire diameter used. Mount the wire coil and slip the wire 

into the feeder and torch sheath. Remove the gas nozzle 

and unscrew the contact tip (located on the end of the 

torch). Turn on the machine. Press the torch trigger 

until the wire protrudes or use switch 

(13)

. Tighten the 

contact tip and replace the gas nozzle.

3.4 GAS CONNECTION

-   Secure the welding grade shielding gas cylinder 

in an upright position by chaining it to a suitable 

stationary support to prevent falling or tipping.

-   Connect the regulator inlet connection to cylinder 

or pipeline and tighten it firmly but not excessively, 

with a suitable spanner.

-  Connect and tighten the outlet hose firmly.

-  Open the reducer of the cylinder and adjust the gas 

flow to 8 – 10 l/min.

CAUTION: Make sure the gas used is compatible with 

the material to be welded.

3

2

1

6

5

Figure 1

4

7

8

9

10

14

15

16

Figure 2

11
12

13

Figure 3

Gas cylinder

Pressure reduce

Shielding 

gas

Welding torch

Power source with 

wire feed uni

Earth clamp

Workpiece

Summary of Contents for WK MIG 3140

Page 1: ...www weldkar com INVERTER WELDER WK MIG 3140 welding equipment NED pag 2 ENG page 11 DEU Seite 20 FRA page 30 GEBRUIKSAANWIJZING INSTRUCTION MANUAL BEDIENUNGSHANDBUCH MODE D EMPLOI...

Page 2: ...MOGEN ALLEEN DOOR GEKWALIFICEERDE PERSONEN WORDEN UITGEVOERD Hoewel de informatie in deze handleiding het beste oordeel van de fabrikant weerspiegelt zal deze laatste geen verantwoordelijkheid voor h...

Page 3: ...eiligheidsharnas om vallen te voorkomen bij het werken boven het vloerniveau 15 Houd alle panelen en afdekkingen goed op hun plaats WAARSCHUWING BOOGSTRALEN kunnen de ogen en de huid verbranden LAWAAI...

Page 4: ...de lichaamsbescherming om de huid te beschermen WAARSCHUWING Indien beschadigd kunnen GASFLESSEN ontploffen Schermgasflessen bevatten gas onder hoge druk Indien beschadigd zal een gasfles kunnen explo...

Page 5: ...en rondom de kabels en de generatoren De magnetische velden geproduceerd door hoge stroom kunnen de functionering van pacemakers be nvloeden De dragers van vitale elektronische apparatuur pacemakers m...

Page 6: ...actdoos hulpvermogen 115V 15A t t1 t2 X IPM MPM t V Zekering Draadaanvoerfunctie Voorstroomtijd Nastroomtijd Puntlastijd Puntlasmodus Indrukken om de draadtoevoer en het lassen te starten loslaten om...

Page 7: ...2 INOX 0 8 1 0 1 2 AL 0 8 1 0 1 2 CuSi3 0 8 1 0 Max draadspoeldiameter 300 mm 15 kg Aandrijving 4 rols Beschermingsklasse IP 23 Isolatieklasse H Gewicht 25 kg Afmetingen LxBxH 610 x 240 x 430 mm 2 3 V...

Page 8: ...orgt voor een rustige afgevlakte lasboog in het kortsluitboog gebied 15 Instelknop Regelt afhankelijk van de geselecteerde LED de lasstroom LED 10 of draadaanvoersnelheid bij MIG lassen LED 9 16 Inste...

Page 9: ...mm Meters per minuut Voltage Staal SG 2 0 8mm 1 0mm 4 2m min 16 3V 1 5mm 5 5m min 17 0V 2 0mm 6 8m min 17 2V 2 5mm 8 2m min 17 9V 3 0mm 10 0m min 19 7V 3 5mm 11 6m min 21 4V 4 0mm 13 0m min 22 8V 5 0...

Page 10: ...draadaanvoerrol indien versleten Draad aangewreven tegen de slecht uitgelijnde geleiders en de mogelijke draadaanvoer is beperkt Verkeerde uitlijning van inlaat uitlaatgeleiders Aanvoer geblokkeerd d...

Page 11: ...11 INVERTER WELDER WK MIG 3140 INSTRUCTION MANUAL INSTRUCTION MANUAL ENGLISH...

Page 12: ...ION OPERATION MAINTENANCE AND REPAIR WORK PERFORMED ONLY BY QUALIFIED PEOPLE While the information contained in this Manual represents the Manufacturer s best judgement the Manufacturer assumes no lia...

Page 13: ...process produce intense heat and strong ultraviolet rays that can burn eyes and skin Noise from some processes can damage hearing 1 Wear a welding helmet fitted with a proper shade of filter to protec...

Page 14: ...d gas cylinders associated equipment and Safety Standards WARNING MOVING PARTS can cause injury Moving parts such as fans rotors and belts can cut fingers and hands and catch loose clothing 1 Keep all...

Page 15: ...sec Frequency Negative Positive Direct Current DC Protective Earth Ground Line Line Connection Auxiliary Power Receptacle Rating Auxiliary Power Art A 10663_AB 115V 15A t t1 t2 X IPM MPM t V Fuse Wire...

Page 16: ...t Wire sizes that can be used FE 0 6 0 8 1 0 1 2 INOX 0 8 1 0 1 2 AL 0 8 1 0 1 2 CuSi3 0 8 1 0 Max wire spool size 300 mm 15 kg Wire feeder 4 roll Protection Class IP 23 Isolation Class H Weight 25 kg...

Page 17: ...gulates the welding current LED 10 or wire speed in MIG welding LED 9 16 Setting knob regulates welding voltage 3 2 REEL FITTING SEQUENCE 1 Mount the wire reel 2 The wire reel hub incorporates a frict...

Page 18: ...29 5V Steel SG 2 1 0mm 1 5mm 3 4m min 15 6V 2 0mm 4 4m min 16 3V 2 5mm 5 5m min 17 1V 3 0mm 6 4m min 18 0V 3 5mm 7 4m min 19 3V 4 0mm 9 0m min 23 0V 5 0mm 10 0m min 26 0V 6 0mm 12 0m min 29 0V 7 0mm...

Page 19: ...ize Use a feed roller matched to the size you are welding Replace feed roller if worn Wire rubbed against the mis aligned guides and reduced wire feedability Mis alignment of inlet outlet guides Liner...

Page 20: ...INVERTER WELDER WK MIG 3140 BEDIENUNGSHANDBUCH BEDIENUNGSHANDBUCH DEUTSCH 20...

Page 21: ...andten Verfahren Teil 2 Elektrisch enthalten INSTALLATIONS BEDIENUNGS WARTUNGS UND REPARATURARBEITEN SIND AUSSCHLIESSLICH DURCH QUALIFIZIERTES PERSONAL AUSZUF HREN Die in diesem Handbuch enthaltenen I...

Page 22: ...er an 11 Ber hren Sie die Elektrode nicht solange sie in Kontakt mit dem Werkst ck Erdungs stromkreis ist 12 Verwenden Sie nur Ausr stungsteile die sich in einem gutem Wartungszustand befinden Reparie...

Page 23: ...ecke am Fu boden an Schott oder Zwischenw nden ein Brand auf der dem Schwei er abgewandten Seite entstehen kann 7 F hren Sie an geschlossenen Beh ltern wie z B Tanks oder Trommeln keine Schwei arbeite...

Page 24: ...kzeug Funkenbildung 4 Verwenden Sie das Schwei ger t nicht zum Aufladen von Batterien oder als Starthilfe f r Fahrzeuge 5 Beachten Sie die Polarit t und der Batterie HINWEIS Hinweise zum Schwei en und...

Page 25: ...arten des Drahtvorschubs und zum Schwei en dr cken zum Stoppen loslassen Ausblasen mit Gas Zoll pro Minute Meter pro Minute Schwei pistole R ckbrennzeit Vierstufiger Schalterbetrieb Zweistufiger Schal...

Page 26: ...pannung 53 Volt Schwei bare Dr hte FE 0 6 0 8 1 0 1 2 INOX 0 8 1 0 1 2 AL 0 8 1 0 1 2 CuSi3 0 8 1 0 Max Drahtspule Durchmesser 300 mm 15 kg Vorschubeinheit 4 rollen Schutzgrad IP 23 Isolationsklasse H...

Page 27: ...er f r folgende Einstellungen Schwei strom LED 10 Drahtvorschubgeschwindigkeit f r das MIG Schwei en LED 9 16 Schwei spannung Drehknopf 3 2 DEN EINBAU DER SPULE 1 Die Drahtspule montieren 2 In die Nab...

Page 28: ...5mm 11 6m min 21 4V 4 0mm 13 0m min 22 8V 5 0mm 14 0m min 26 1V 6 0mm 15 0m min 29 5V Stahl SG 2 1 0mm 1 5mm 3 4m min 15 6V 2 0mm 4 4m min 16 3V 2 5mm 5 5m min 17 1V 3 0mm 6 4m min 18 0V 3 5mm 7 4m mi...

Page 29: ...t verschlissen oder hat die falsche Gro e Vorschubrolle entsprechend der verwendeten Verschlissene Vorschubrolle ersetzen Draht scheuert an den nicht korrekt ausgerichteten F hrungen Drahtvorschub ist...

Page 30: ...30 INVERTER WELDER WK MIG 3140 MODE D EMPLOI MODE D EMPLOI FRAN AIS 30...

Page 31: ...TALLATION DE FONCTIONNEMENT D ENTRETIEN ET DE REPARATION NE DOIVENT ETRE EFFECTUEES QUE PAR DU PERSONNEL QUALIFIE Si les informations contenues dans ce manuel refl tent le discernement du fabricant ce...

Page 32: ...ur viter de tomber si l on travaille en hauteur 15 Maintenir en place tous les panneaux et les couvercles en toute s curit MISE EN GARDE LES RAYONS DE L ARC peuvent br ler les yeux et la peau tandis q...

Page 33: ...ommand s 2 Porter des v tements appropri s pour prot ger la peau MISE EN GARDE Quand ils sont ab m s les CYLINDRES peuvent exploser Les cylindres des gaz de protection contiennent du gaz haute pressio...

Page 34: ...des champs lectromagn tiques autour des c bles ou des g n rateurs Les champs magn tiques provoqu s par des courants lev s peuvent interf rer avec le fonctionnement des stimulateurs cardiaques C est po...

Page 35: ...puyer pour d marrer l avancement du fil et le soudage rel cher pour l arr ter Purge du gaz Pouces par minute M tres par minute Pistolet de soudage Temps de reprise de feu Fonctionnement de la g chette...

Page 36: ...il employer FE 0 6 0 8 1 0 1 2 INOX 0 8 1 0 1 2 AL 0 8 1 0 1 2 CuSi3 0 8 1 0 Bobine de fil tra ner max 300 mm 15 kg D vidoir 4 galets Classe de protection IP 23 Classe d isolation H Poids 25 kg Dimens...

Page 37: ...vitesse du fil en soudure MIG LED 9 16 Bouton de r glage r gle la tension de soudage 3 2 LE MONTAGE DE LA BOBINE DE FIL 1 Monter la bobine du fil 2 Le groupe de la bobine de fil comprend un frein fric...

Page 38: ...1 0mm 1 5mm 3 4m min 15 6V 2 0mm 4 4m min 16 3V 2 5mm 5 5m min 17 1V 3 0mm 6 4m min 18 0V 3 5mm 7 4m min 19 3V 4 0mm 9 0m min 23 0V 5 0mm 10 0m min 26 0V 6 0mm 12 0m min 29 0V 7 0mm 12 8m min 30 2V IN...

Page 39: ...n s il est us Fil frottant contre les guides mal align s et alimentation r duite du fil Mauvais alignement des guides d entr e de sortie Rev tement bloqu par les copeaux Des quantit s majeures de cope...

Page 40: ...G3B G4A G4B MOTOR GUN EV THERMISTOR WIRE FEED GAS VOLTAGE WIRE SPEED WAVE CONTROL C2 C1 4 3 2 1 24V 24V C31 24V 2 1 2 1 3 4 A B C A B C 21 43 D T1A T1B T3A T3B T2A T4A T2B T4B T1 OUT OUT 1 2 1 2 1 2 1...

Page 41: ...41 eng deu fra ned B ONDERDELENTEKENING SPARE PARTS LIST ERSATZTEILZEICHNUNG SCH MA DES PI CES...

Page 42: ...1 22 Heat sink 1 for IGBT 1 23 FRD 12 Insulation block 3 12 24 MUR PCB 1 25 Heat sink 1 1 26 Heat sink 2 1 27 Support pillar 2 28 Main transformer 1 29 Holder for transformer 1 Pos Description Quantit...

Page 43: ...43 eng deu fra ned...

Page 44: ...www weldkar com welding equipment...

Reviews: