Temperature Control test: measuring the cavity temperature
Re-calibrating the temperature sensor / thermocouple with the SRB is normally only required when the
thermocouple has been replaced or the appliance is under or over cooking.
1.
Place the probe of a temperature reader on the
metal plate in the centre of the oven cavity and
close the door.
2.
Select ‘Temperature Control Test’ from the
service mode tests.
The cavity heats up and cycles at the maximum
set point temperature over 30 minutes.
Once the appliance is up to maximum
temperature, check for a stable temperature
reading.
Select the red 'X' from the status screen to finish
the test, if necessary.
3. If the temperature reading is different to the
maximum set point, scroll up to select TEMP.
COMP. (Temperature Compensation) and enter
the password "TCOMP".
4. Enter the figure from the temperature reader on
the keypad and select OK to calibrate the SRB
to the temperature sensor (thermocouple).
5. Retest to check that the cavity temperature reading is the same as the oven maximum set point temperature.
6. If the temperature reading is stable, repeat the Temperature Control Test procedure.