High voltage components (casing removed)
High Voltage Transformer test
Ensure the following requirements have been met before starting the test:
•
The appliance has been disconnected from the power supply and protective measures have been taken to ensure
the power cannot be switched on again.
•
The appliance is cool.
•
The high voltage capacitors are discharged before commencing work.
•
Anti-static precautions have been taken.
•
The casing of the appliance has been removed.
•
High voltages and large currents are present at the high voltage capacitor.
•
It is very dangerous to work near this part when the oven is on.
•
NEVER make any voltage measurements at the high voltage circuits, including the magnetron filament.
1. Remove all connections from the transformer.
2.
Using a Digital Multi-Meter (DMM), check the resistance of the windings.
Results should be as follows:
•
Mains winding between tags, approx. 0.6
–
1
Ω
.
•
High Voltage winding, approx. 60
Ω
.
•
Filament winding between terminals, less than 1
Ω
.
It is possible to makes this test across the orange cables of the
magnetron.
3.
Using the DMM, test the insulation resistance between:
•
Primary winding and chassis. Pass if reading is over 10 M
Ω
•
Filament winding and chassis. Pass if reading is over 10 M
Ω
Note: One end of the High Voltage winding is connected to the chassis, so this is not tested.
Summary of Contents for Merrychef eikon e1s
Page 11: ...11 eikon e1s Service and repair guide Section 1 Safety ...
Page 43: ...43 eikon e1s Service and repair guide Section 2 Operations and Installation ...
Page 82: ...82 eikon e1s Service and repair guide Section 3 Service and Repair ...
Page 147: ...147 eikon e1s Service and Repair Guide Circuit diagrams ...