15.
✔
Probe
fully
inserted
in tube
Wiring is properly
connected
D/ LOW WATER LEVEL PROBE:
Probe
bypassed
by running
(A)
an
additional wire
Probe properly
attached
✔
✘
Probe
bypassed by
(B)
grounding the
connecting wire
✘
(A)
(B)
E/ SAFETY THERMOSTAT
Installation Check
:
Incorrect Installations
1.
Safety thermostat probe
is not completely
inserted into tubing
(except KET-3-T that
has a small loop).
2.
Safety thermostat probe
is removed from tubing.
3.
Safety thermostat
electrical connection is
bypassed.
C/ CONTACTOR TEST
1.
Remove power to unit.
2.
Remove nut holding component mounting plate to
console.
3.
Pull plate out and place on top of console. (Depending on how
the installer wired the kettle you may have to remove the
supply wire and reconnect).
4.
Physically push in on contacts of each contactor to check
for free movement. Replace contactor(s) if required.
Functional Test:
1.
Turn main power on at fused
disconnect switch.
2.
Turn kettle on and set temperature
to maximum.
3.
Green light will come on and
contactors close.
4.
Tilt kettle over. After approximately
a five-second delay the red light
will come on, green light go off
and the contactors will disengage.
5.
Turn kettle upright. Green light will
come back on and contactors
reengage.
6.
Turn kettle off
7.
If unit does not function as above,
make required repairs.
8.
Disconnect main power at fused
disconnect switch.
Installation Check:
Correct
Installation
✘
Probe
removed
partially
✘
Probe
removed
completely
✘
Thermostat
electrically
bypassed
1
2
3