33
WAS.handling Windows – Program
Group general (continuation):
stop input:
Wiring Stop – Input: HIGH or LOW active
Unlike Quickstop, the axes remain enabled.
Waittime Enable: Switch-on delay for ENABLE signal.
Group drive:
Acopos Type:
This shows the drive type.
switch frequency: Modulation frequency of output stage
phase monitor
Monitors, whether all 3 power phases are available to the drive. If only one phase is
connected, deactivate this monitoring.
Group find motor phase:
method:
Method for determining the commutation angle.
Parameter must only be changed by WEISS service technician.
current:
Power used for inphasing.
Group motor:
motor type:
The motor type is pre-set and must not be changed.
temp sensor:
Here you can select the type of motor temperature sensor.
motor torque:
Display of the maximum motor torque.
Part 5:
Part 5 displays the current position, speed and motor current.