15
WAS.handling Windows – Program
4.2.5 Demo sequence
In principle, the demo sequence works like the drive sequence. Difference: At the end of the sequence the
program jumps back to line 1. The demo sequence is used for presentations at trade shows and for starting
up of operations so the axes „can simply be moved“. Furthermore, the most important functions for operating
the HP140 can be found here.
Functions in detail:
Cycle time:
Drive time of the axis with active stopwatch function.
Step no.:
Displays the active step.
Reference point:
When the machine knows its reference point, TRUE is displayed.
Override:
This denotes a speed override "over all." This means that all speed values are
multiplied by this override (0.01 per cent…100.00 per cent).
PC
PLC:
For saving the demo sequence to the PLC.
Start:
Starts the demo sequence.
Stop:
Stops after the last command.
Quick Stop:
The sequence is aborted immediately.
Reference:
A reference drive is carried out.
Ackn:
Acknowledge error.
Save:
Save this demo sequence to PC harddrive.
Load:
Load this demo sequence from PC harddisk.
(It must then be transferred to the control system using "PC
PLC").
Delete:
Deletes all entered commands.