5.3 Condensate connection
Only fit condensate outlet to the unit if the drainage is piped, otherwise let condensate
drip away freely.
CAUTION
Damage to the building structure caused by condensate
Condensate can damage and soil building structure.
▶
Install condensate hose in such a way that the condensate can seep into the
ground unimpeded and without freezing, and does not cause damage to the build-
ing structure.
▶
If necessary, fit condensate hose with internal Ø of 16 mm supplied by others.
✓
Condensate can drain away unimpeded.
▶
Do not discharge the condensate directly into the sewer due to the risk of corrosion.
Weishaupt recommends trace heating for the condensate pan (accessory) if the
drainage is piped.
Installation and operating instruction
Outdoor unit WWP L 15 ARS