Note
When switching on the automatic, an upward travel of the receiver
is triggered (provided that sensors are programmed in the
receiver).
End position
The end position is the point where the roller shutter/venetian blind
is in the upper or lower position. In this position, the sun protection
system is completely extended or retracted.
Intermediate position
The intermediate position is a freely-selectable position of the
shutter/blind between the top and bottom end position. This can
be approached from the top end position after programming is
complete.
For this, press the
Down
button briefly
twice
successively.
In venetian blind mode, any programmed tilting is carried out auto-
matically following the intermediate position.
Ventilation/Tilting
The ventilation/tilting position is a freely selectable position of the
shutter/blind between the top and bottom end position. Using this
function, you can raise the roller shutter from the lower end posi-
tion until the ventilation gaps are again open. With venetian blinds,
the slats are inverted.
For this, press thee
UP
button briefly
twice
successively.
Explanation of functions
14 | EN
EN | 15
Programming a transmitter/channel
Programming a transmitter/channel
PREREQUISITE!
The receiver must be installed.
!
1. Disconnect the fuse - and reconnect after a few seconds.
The receiver is now in programming mode for about 5 minutes.
2. Stand with the BiEasy 1MW-3V in front of the shutter/blind.
3. Briefly press the programming button
P
.
The shutter/blind will automatically move up and down (for
approx. 2 minutes).
4. To define the keyboard layout, press the
UP
button on the
BiEasy 1MW-3V (for max. 1 second)
immediately
after the start
of the upward travel.
The shutter/blind will stop for a short time.
5. Press the
DOWN
button on the BiEasy 1MW-3V (for max. 1 sec-
ond)
immediately
after the start of the downward travel.
The shutter/blind stops.
The BiEasy 1MW-3V is now programmed.
UniTec-868
P
Programming buttons
P
(all-purpose)